Results 151 to 160 of about 852,283 (182)
Some of the next articles are maybe not open access.

Model for transient behavior of pulse tube cryocooler

Cryogenics, 2011
Abstract This article describes an investigation of the transient behavior of a small (2.0 W at 85 K) pulse tube cryocooler operating at 120 Hz with an average pressure of 3.5 MPa, capable of relatively fast cool-down from ambient to about 60 K. In a series of experiments, the cold end temperature was measured as a function of time in a complete cool-
Gershon Grossman   +3 more
openaire   +1 more source

Development of the Miniature Pulse Tube Cryocooler

AIP Conference Proceedings, 2004
Fuji Electric has developed a pulse tube cryocooler (PTC) with in‐line configuration with a cooling capacity of 3 W at 70 K and requiring 100 W of electrical input power. The emphasis has been on compactness, lightweight, high performance and low cost.
openaire   +1 more source

Conducted EMI Reduction on the Pulse Tube Cryocooler

IEEE Transactions on Magnetics, 2009
Pulse tube (PT) cryocoolers can be used to cool SQUIDs, however their electromagnetic interference (EMI) through the conducted high frequency noise currents are normally too large to operate SQUIDs. In this paper, high frequency noise currents of a pulse tube cryocooler system are simultaneously observed at several critical points to analyze conducting
M.J. Eshraghi   +3 more
openaire   +1 more source

Intermediate cooling from pulse tube and regenerator in a 4K pulse tube cryocooler

Cryogenics, 2008
Abstract This paper introduces intermediate cooling by thermally attaching heat exchangers on the second stage pulse tube and regenerator in a commercial 4 K pulse tube cryocooler. Due to the large enthalpy flow in the 2nd stage pulse tube and regenerator, both intermediate heat exchangers on the pulse tube and regenerator can provide cooling ...
openaire   +1 more source

Pulse Tube Cryocoolers

2022
John M. Pfotenhauer, Xiaoqin Zhi
openaire   +1 more source

Development of a Light Weight Pulse-Tube Cryocooler

AIP Conference Proceedings, 2004
Examinations were done of a small‐size Stirling‐type pulse‐tube cryocoolers developed for cooling high‐temperature superconductor devices and semiconductor sensors. To satisfy the requirements for use in such devices, the Stirling‐type pulse‐tube cryocooler WE‐SP2000, the conventional model, needed further improvement.
openaire   +1 more source

Pulse tube cryocoolers for cooling infrared sensors

SPIE Proceedings, 2000
This paper reviews recent advances in pulse tube cryocoolers and their application for cooling infrared sensors. There are many advantages of pulse tube cryocoolers over Stirling cryocoolers associated with the absence of moving parts in the cold head. Efficiencies have been improved considerably in the last few years to where they equal or even exceed
openaire   +1 more source

Pulse Tube Refrigeration–A New Type of Cryocooler

Japanese Journal of Applied Physics, 1987
A variation of the Stirling cryocooler, known as a pulse tube refrigerator, requires only one moving part - a pressure wave generator at room temperature. The Stirling cryocooler requires in addition a moving displacer at low temperatures to cause a phase shift between pressure and mass flow rate that leads to a refrigeration effect.
openaire   +1 more source

Linearized theory for pulse tube cryocooler performance

AIAA Journal, 1994
A linearized theory, which assumes small pressure perturbations, is presented for the performance of orificetype pulse tube cryocoolers. The effect of gas-to-wall heat transfer within the pulse tube is included. Analytical expressions are derived for pulse tube flow properties and refrigeration power as functions of parameters K, Hl9 and v, which ...
openaire   +1 more source

Efficient 10 K Pulse Tube Cryocoolers

2005
Two 10 K pulse tube cryocoolers, Models PT805 and PT810, have been developed and commercialized at Cryomech to provide cooling from 8 K to 20 K. The PT805 provides 3.5 W at 10 K and 48 W at 80 K, simultaneously, for 4.6 kW power input. The PT810 provides 10 W at 10 K and 40 W at 49 K, simultaneously, for 7.6 kW power input. These pulse tube cryocoolers
openaire   +1 more source

Home - About - Disclaimer - Privacy