Results 61 to 70 of about 1,964,125 (283)
Objective Systemic sclerosis (SSc) is characterized by cardiovascular risk excess not fully explained by traditional factors. Whether the severity of microvascular damage correlates with structural subclinical atherosclerosis remains unclear. We investigated the relationship between nailfold videocapillaroscopy (NVC) abnormalities and carotid ...
Eugenio Capparelli +13 more
wiley +1 more source
Urbanization as a risk factor for aortic stiffness in a cohort in India. [PDF]
Urbanization is associated with higher prevalence of cardiovascular disease worldwide. Aortic stiffness, as measured by carotid-femoral pulse wave velocity is a validated predictor of cardiovascular disease. Our objective was to determine the association
Laura Corlin +9 more
doaj +1 more source
Adaptive Foam 3D Printing of Ultralight and Multifunctional Materials
Adaptive foam 3D printing, enabled by expandable microspheres, imparts cellular structures to thermoplastic and thermosetting polymers, manufactured through a variety of processes including fused filament fabrication, direct ink writing, digital light processing, and inkjet printing.
Nariman Rajabifar, Amir Ameli
wiley +1 more source
Response of a Hypersonic Boundary Layer to Freestream Pulse Acoustic Disturbance
The response of hypersonic boundary layer over a blunt wedge to freestream pulse acoustic disturbance was investigated. The stability characteristics of boundary layer for freestream pulse wave and continuous wave were analyzed comparatively.
Zhenqing Wang, Xiaojun Tang, Hongqing Lv
doaj +1 more source
Pulse wave analysis with diffusing-wave spectroscopy
Hypertension is a major risk factor for cardiovascular disease and thus at the origin of many deaths by e.g. heart attack or stroke. Hypertension is caused by many factors including an increase in arterial stiffness which leads to changes in pulse wave velocity and wave reflections.
Belau, Markus +2 more
openaire +3 more sources
Binder‐free laser powder bed fusion of 8YSZ with a femtosecond laser is used to map process windows linking scan strategy, heat accumulation, and grain growth. Time‐resolved thermography and simulations reveal thermal regimes that enable continuous, vitrified, and fine‐grained 8YSZ surface layers without absorptive additives and demonstrate ...
Markus Kühn +5 more
wiley +1 more source
Edible electronics needs integrated logic circuits for computation and control. This work presents a potentially edible printed chitosan‐gated transistor with a design optimized for integration in circuits. Its implementation in integrated logic gates and circuits operating at low voltage (0.7 V) is demonstrated, as well as the compatibility with an ...
Giulia Coco +8 more
wiley +1 more source
Background Conduit arteries, especially the aorta, play a major role in ensuring efficient cardiac function and optimal microvascular flow due to their viscoelastic properties.
Sigita Kazune +4 more
doaj +1 more source
Aortic Pulse Wave Velocity and Carotid-Femoral Pulse Wave Velocity: Similarities and Discrepancies [PDF]
The objectives of this study were to determine the relationship between carotid-femoral (cfPWV) and aortic pulse wave velocity (aPWV) and to compare their modulators and association with coronary artery disease (CAD). We studied 107 consecutive patients (68 men) with a mean age of 60.49+/-8.31 years who had stable angina and had been referred for ...
Podolec, Piotr +9 more
openaire +3 more sources
Ferroelectric tunnel junction devices based on epitaxial undoped ferroelectric HfO2 films demonstrate stable switching endurance of over 106 switching cycles, low write voltages of ±3 V, 16 measured resistance states, and neuromorphic capability.
Markus Hellenbrand +13 more
wiley +1 more source

