Results 111 to 120 of about 1,130 (256)
To address the problems of low inversion accuracy and poor noise resistance in pulsed eddy current (PEC) grounding grid depth detection, this study proposes a novel inversion model (IE-CBiLSTM).
Yonggang Yue +6 more
doaj +1 more source
Abstract figure legend Peripheral tactile afferents exhibit a wide range of response patterns to a pure frequency vibratory stimulus. Some afferents, including those remote from the stimulus site, fire at lower rates as they do not respond to every vibration cycle of the stimulus.
Alwin So +4 more
wiley +1 more source
ABSTRACT Purpose To develop a reconstruction framework for DW‐PROPELLER‐EPI that improves image quality and SNR efficiency under per‐blade acceleration while minimizing EPI‐related artifacts, enabling high‐resolution diffusion‐tensor imaging (DTI) with fewer blades.
Hailin Xiong +7 more
wiley +1 more source
A Sub‐Microsecond Switch Enabling SWIFT 23Na Imaging at 10.5 T
ABSTRACT PurposeTo enable sodium SWIFT imaging, which is a zero‐echo time imaging technique, at ultra‐high magnetic fields through the development of custom electronics hardware, and to showcase this capability with in vivo imaging results. MethodsThe custom hardware developed consists of a high‐speed optical trigger with 10 ns resolution, an in‐bore ...
Russell L. Lagore +10 more
wiley +1 more source
Design of an 8‐Channel Transmit 32‐Channel Receive 11.7T Head Coil and Evaluation of SNR Gains
ABSTRACT Purpose To design and develop an 8‐channel transmit 32‐channel receive 11.7T head coil for the strongest human MRI scanner to date, demonstrate safety, and evaluate signal‐to‐noise ratio (SNR) gains compared to 7T, the most used ultra‐high‐field (UHF) platform.
Son Chu +8 more
wiley +1 more source
In oil and gas extraction, ferromagnetic metal casings serve as critical infrastructure to ensure the safety of hydrocarbon transport. However, under high-temperature and high-pressure conditions, casings buried deep underground are prone to deformation,
DENG Yong, SONG Dilin, SUN Hu
doaj
ABSTRACT Purpose To develop a phase‐corrected time‐interleaved multi‐echo gradient echo Cartesian acquisition with spiral profile ordering (TIMGRECASPR) for abdominal large‐FOV proton density fat fraction (PDFF) mapping at 3 T, demonstrating its sampling flexibility and inherent self‐gating capabilities at high isotropic resolutions.
Philipp Braun +7 more
wiley +1 more source
ABSTRACT Purpose To integrate MR‐based servo navigation in MPRAGE and 3D‐TSE sequences and demonstrate its potential for prospective head motion correction in structural imaging. Methods Repeated modules of servo navigators were inserted before each preparation pulse of MPRAGE and 3D‐TSE sequences (before‐prep) for rapid convergence of motion parameter
Matthias Serger +7 more
wiley +1 more source
ABSTRACT Introduction Despite the relevance of neuromuscular electrical stimulation (NMES) dosimetry, it is unclear whether increasing the self‐reported tolerated amplitude enhances acute neuromuscular responses. Objective To investigate the acute effects of varying NMES amplitude and type of induced contraction on quadriceps isometric torque (IT) and ...
Jhonatan Zini dos Anjos +5 more
wiley +1 more source

