Results 81 to 90 of about 10,408 (217)

A modal approach for the solution of the non-linear induction problem in ferromagnetic media

open access: yes, 2016
The non-linear induction problem in ferromagnetic media is solved using the fixed-point iteration method, where the linearized problem at each iteration is treated by means of a modal approach.
Skarlatos, Anastassios   +1 more
core   +1 more source

Polymerized Pro‐Estrogen Microneedles via Two Photon Polymerization

open access: yesMacromolecular Rapid Communications, EarlyView.
Acrylic pro‐drugs of 17β‐estradiol were subjected to spatially controlled two‐photon polymerization to create bespoke microneedle geometries with potential biomedical applications for long‐term transdermal hormone delivery. ABSTRACT Two‐photon polymerization (TPP) is a powerful technique to create microscale structures with high precision, offering ...
Yang Lou   +6 more
wiley   +1 more source

A Stopped‐Flow Instrument for Millisecond Timescale Reaction Monitoring on a Standard NMR Spectrometer

open access: yesMagnetic Resonance in Chemistry, EarlyView.
A new stopped‐flow instrument allows kinetic measurements of reactions 10 milliseconds after initiating them by mixing in a flow cell inserted into a standard NMR probe and spectrometer. High‐speed video, pressure and NMR line‐shape data are used to characterise mixing and stopping, and a protodeboronation reaction with a 5‐millisecond half‐life used ...
Andrew M. R. Hall   +6 more
wiley   +1 more source

Quantitative Diffusion and T2 Mapping Using RF‐Modulated Phase‐Based Gradient Echo Imaging

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To introduce and evaluate the feasibility of a novel RF‐phase modulated gradient echo (GRE) method for quantitative diffusion MRI, aimed at mitigating geometric distortion and enabling high‐resolution 3D quantitative diffusion/T2 mapping as a complementary alternative to conventional DWI.
Daiki Tamada   +4 more
wiley   +1 more source

Evaluation of Pulse Eddy Current for Autonomous Airborne Inspections

open access: yesIEEE Sensors Letters
Unmanned Aerial Vehicles (UAVs) integrated with Pulsed Eddy Current (PEC) technologies present a potential solution for Non-Destructive Testing (NDT) in environments where manual inspection is impractical or hazardous. PEC inspections conducted via UAVs facilitate remote structural health monitoring and offer invaluable thickness measurements for ...
Taiyi Zhao   +6 more
openaire   +2 more sources

Data fusion algorithm for pulsed eddy current detection

open access: yesIET Science, Measurement & Technology, 2007
A weighted data fusion algorithm based on matching pursuit (MP)-wavelet packet (WP) atomic decomposition and its applications in pulsed eddy current (PEC) non-destructive testing systems for estimation of feature parameters is presented. MP-WP atomic decomposition is used to estimate each noise-free pulse response from its noisy observation of a single-
Yang G, Tian GY, Que PW, Li Y
openaire   +2 more sources

Fat/Water Separation at 7 T Using a 3D Radial Sequence With Quasi‐Continuous Echo Times

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To achieve a reliable fat/water separation (FWS) at 7 T using a new 3D radial sequence and reconstruction workflow with quasi‐continuous TE sampling. Methods A 3D radial density‐adapted sequence with quasi‐continuous TE sampling was developed for a 7 T whole‐body MRI system.
Matthias Rohe   +9 more
wiley   +1 more source

Influence of cross-sectional shape on flow patterns in an open-channel confluence [PDF]

open access: yes, 2015
The state-of-the-art hydrodynamic knowledge on schematized open-channel confluences is largely based on laboratory experiments in channels with a rectangular cross-section.
Creëlle, Stéphan   +2 more
core   +1 more source

A Numerical Alternative to MR Thermometry for Safety Validation of Multi‐Channel RF Transmit Coils

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose This study proposes a numerical technique to estimate peak local specific absorption rate (SAR) uncertainty of multi‐channel RF coils during the process of safety validation as an alternative to experimental temperature and electric‐field measurements, and demonstrates its use to enable human studies at 10.5 T.
Alireza Sadeghi‐Tarakameh   +14 more
wiley   +1 more source

Autonomy for MRI Field Cameras: Synchronization, Self‐Calibration, and Sequence Detection

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose This work aims to provide a workflow for operating NMR field probes in MR scanners independently of pulse programming, scanner TTL trigger pulses and dedicated calibration sequences. Methods An independent timing system and limited prior knowledge about relative probe positions enable synchronous field measurement, probe position ...
Oskar Björkqvist, Klaas P. Pruessmann
wiley   +1 more source

Home - About - Disclaimer - Privacy