Results 41 to 50 of about 179,443 (327)

Techno-Economic Comparison of Brayton Pumped Thermal Electricity Storage (PTES) Systems Based on Solid and Liquid Sensible Heat Storage

open access: yesEnergies, 2022
To integrate large shares of renewable energy sources in electric grids, large-scale and long-duration (4–8+ h) electric energy storage technologies must be used.
Guido Francesco Frate   +2 more
doaj   +1 more source

Multi-Time-Scale Coordinated Operation of a Combined System with Wind-Solar-Thermal-Hydro Power and Battery Units

open access: yesApplied Sciences, 2019
The grid connection of intermittent energy sources such as wind power and photovoltaic power generation brings new challenges for the economic and safe operation of renewable power systems.
Dongying Zhang   +4 more
doaj   +1 more source

Wind-Thermal-Nuclear-Storage Combined Time Division Power Dispatch Based on Numerical Characteristics of Net Load

open access: yesEnergies, 2020
In order to satisfy the strategic needs of energy sustainable development, renewable energy has developed rapidly and the power systems have been transformed to a new generation of power systems. In the renewable energy power generation technologies, the
Xin Sui   +7 more
doaj   +1 more source

Electrical energy storage using a supercritical CO2 heat pump

open access: yesEnergy Reports, 2022
This work proposes a new Pumped Thermal Energy Storage (PTES) configuration that works with supercritical CO2 as the working fluid and molten salts as the thermal storage fluid. The net work generated by this novel proposal is 12.46 MW in the load and 10
Paul Tafur-Escanta   +4 more
doaj   +1 more source

Ubiquitous energy storage [PDF]

open access: yes, 2005
This paper presents a vision of a future power system with "ubiquitous energy storage", where storage would be utilized at all levels of the electricity system.
Ault, G. W.   +4 more
core   +1 more source

A Multi-Time Scale Scheduling Model for Power Generation Systems with a High Proportion of New Energy Including Pumped Storage Power Stations

open access: yesShanghai Jiaotong Daxue xuebao
Aimed at the accommodation problem of a high proportion of new energy connected to the power grid, a multi-time scale coordinated scheduling model for power generation systems with a high proportion of new energy including pumped storage power stations ...
GU Huijie, ZHOU Huafeng, PENG Chaoyi, HU Yaping, ZHAO Xinyi, XIE Jun, SHI Xionghua
doaj   +1 more source

Joint Peak Shaving Energy Consumption Optimization Model and Simulation Analysis of Pumped Storage Power Unit and Coal-fired Power Units

open access: yesChemical Engineering Transactions, 2016
The regional power grid is mainly a thermal power system, so it is hard to meet increasing the need of difference between peak and valley loads and the demand of peak-load regulation.
H.W. Zhang, J. Zhao
doaj   +1 more source

Harnessing Fungal Biowelding for Constructing Mycelium‐Engineered Materials

open access: yesAdvanced Engineering Materials, EarlyView.
Mycelium‐bound composites (MBCs) offer low‐carbon alternatives for construction, yet interfacial bonding remains a critical challenge. This review examines fungal biowelding as a biocompatible adhesive, elucidating mycelium‐mediated interfacial mechanisms and their role in material assembly. Strategies to optimize biowelding are discussed, highlighting
Xue Brenda Bai   +2 more
wiley   +1 more source

Muti‐units day‐ahead scheduling involving the pumped storages and considering deep‐load regulation

open access: yesThe Journal of Engineering
This paper presents a day‐ahead scheduling for multi‐energy entities. The deep load regulation involving pumped storages, which refers to deep peak regulation, is adopted to address the impact of wind power and photovoltaic (PV) uncertainties, thereby ...
Yudong Tan   +4 more
doaj   +1 more source

High average power 1314 nm Nd:YLF laser, passively Q-switched with V:YAG [PDF]

open access: yes, 2013
A 1314 nm Nd:YLF laser was designed and operated both CW and passively Q-switched. Maximum CW output of 10.4 W resulted from 45.2 W of incident pump power. Passive Q-switching was obtained by inserting a V:YAG saturable absorber in the cavity.
Bollig, C.   +8 more
core   +1 more source