Results 1 to 10 of about 6,801 (159)

Optimization of Energy Consumption in the Pumping Station Supplying Two Zones of the Water Supply System

open access: yesEnergies, 2022
Water supply pumping stations are among the main energy-consuming elements in the water supply system. The energy optimization of a pumping station can significantly affect the energy consumption of a water utility.
Martyna Świętochowska   +1 more
doaj   +3 more sources

The Influence of Geometric Parameters of Pump Installation on the Hydraulic Performance of a Prefabricated Pumping Station

open access: yesEnergies, 2021
A prefabricated pumping station is a new type of pumping station that plays an important role in the construction of sponge cities in developing countries.
Bowen Zhang   +3 more
doaj   +3 more sources

An experimental evaluation of vibration patterns arising from vortex flow in mixed flow pumps a case study in Upper Egypt [PDF]

open access: yesScientific Reports
Mixed flow pumps, characterized by high flow rate and moderate head, are the preferred choice for pumping station installations. Nevertheless, the development of inlet vortices significantly impairs the performance of mixed-flow pumps, threatening ...
Dalia M. S. El-Gazzar   +2 more
doaj   +2 more sources

Seasonal variations drive microbial community structure and nitrogen cycling in sediments of tributary pumping station forebays [PDF]

open access: yesMicrobiology Spectrum
Discharge from tributary pumping stations often impacts mainstream water quality, yet microbial communities and nitrogen metabolism in pumping station forebays remain poorly understood. Therefore, this study investigated the microbial community structure
Xiaofu Wei, Weiwei Song, Siyuan Li
doaj   +2 more sources

Assessing downstream passage of European silver eel at a tidal pumping station: acceleration as a proxy for eel activity [PDF]

open access: yesMovement Ecology
Background To complete their lifecycle, diadromous fish often need to pass anthropogenic barriers in regulated rivers and estuaries (e.g., pumping stations, weirs, hydropower facilities). The safe and timely passage of the endangered catadromous European
I. van der Knaap   +4 more
doaj   +2 more sources

Application of the reliability assessment results for pumping stations’s modernization [PDF]

open access: yesE3S Web of Conferences, 2023
Work on the modernization of irrigation pumping stations in our Republic has a great relevance. Technical modernization and reconstruction of pumping stations require a reliable scientifically based methodological approach. Each pumping station regularly
Kan Eduard   +4 more
doaj   +1 more source

Experimental evaluation of the throughput of the supply channel of pumping stations [PDF]

open access: yesE3S Web of Conferences, 2023
The article experimentally studied the dynamics of sediment inflow into the fore chambers of pumping stations, revealed the intensity of silting, which affects the reliability and operation of the pumping station, and developed recommendations for ...
Bazarov Dilshod   +5 more
doaj   +1 more source

Evaluation Of Thermo Hydraulic Performance Of Passive And Compound Inserts

open access: yesJournal of Applied Science and Engineering, 2023
In the present investigation, the heat transfer and pressure drop performance of a tube in tube heat exchanger fitted with Bakelite helical screw tape and aluminum hemispherical cup shape with threaded core rod insert is experimentally reported for ...
Arvind A. Kapse   +2 more
doaj   +1 more source

Optimal operation of urban tidal drainage pumping station based on genetic algorithm coupled with head-water level successive approximation

open access: yesFrontiers in Energy Research, 2023
Aiming at the method of solving the optimization scheme for urban tidal drainage pumping stations during heavy rainfall below the urban drainage design standard, and the problems such as the mismatch between the head and water level of pumping stations ...
Gong Yi, Zou Wenhao
doaj   +1 more source

Multi-objective Optimization of Cross-basin Water Pump Station Solved by the Pareto Method

open access: yesGuan'gai paishui xuebao, 2022
【Background and objective】 Previous studies have shown that optimal operation of pumping stations needs to frequently adjust the angle, variable speed, start and stop of pump units.
ZHU Bowen   +4 more
doaj   +1 more source

Home - About - Disclaimer - Privacy