Results 41 to 50 of about 6,802 (159)
To improve the adverse flow pattern such as circling and recirculation in the lateral forebay of the lateral inflow pumping station, numerous simulations of the flow during the operation of the pumping station in the pump-sluice complex engineering were ...
XIAO Zhiqiao, FEI Zhaodan, QIAN Shangtuo
doaj
Design of Automatic Control System for Sewage Pumping Station Based on S7-300
In order to solve problem of high cost of running management of relay-contactor control mode commonly used in sewage pumping station at present, the paper proposed a design scheme of automatic control system for sewage pumping station which takes S7-300 ...
CUI Bo +3 more
doaj
Green Transformation of Mining towards Energy Self-Sufficiency in a Circular Economy—A Case Study
This article presents the concept of green transformation of the coal mining sector. Pump stations that belong to Spółka Restrukturyzacji Kopalń S.A. (SRK S.A., Bytom, Poland) pump out approximately 100 million m3 of mine water annually.
Małgorzata Magdziarczyk +3 more
doaj +1 more source
Study on Rectifier Technology in Forebay of Pumping Station
Design of urban drainage pumping stations is susceptible to land area, water pipe networklayout, surrounding terrain conditions and construction requirements.It is often difficult to meetthe requirements of favourable hydraulic conditions in the design ...
SU Zhengyang +4 more
doaj
Optimization of energy saving mode pumping of the main oil pipeline
The current task of increasing the energy efficiency of oil pumping stations (OPS) of main oil pipelines (MOP) is to reduce the consumption of electricity for pumping a unit of commercial product.
N. А. Nosikov, Yu. A. Makarichev
doaj +1 more source
Against the backdrop of global climate change, extreme rainfall events have become increasingly frequent, posing significant challenges to the flood control management of urban river networks.
CHEN Yechao +3 more
doaj +2 more sources
【Background and Objective】Pumping stations with large-deflection-angle lateral intakes often exhibit complex hydraulic behaviors, such as uneven velocity distribution and local recirculation, affecting operational stability and efficiency.
WANG Zhengqian +5 more
doaj +1 more source
To address issues arising from chaotic water flow due to unreasonable pumping station operation and insufficient forebay design, this study took the Yanhuangding pumping station as a typical case.
LI Yun +4 more
doaj +2 more sources
Optimal Pumping Flow Algorithm to Improve Pumping Station Operations in Irrigation Systems
In Spain, irrigated agriculture is the most water-intensive sector, consuming around of 80% of water resources. Moreover, irrigation water distribution systems are the infrastructure by which one-third of water resource losses take place.
Enrique Bonet, María Teresa Yubero
doaj +1 more source

