Results 41 to 50 of about 20,690 (226)
Au/GaOx‐based transparent heaters combine high optical transmittance and low sheet resistance with exceptional thermal stability up to 521°C for over 6 h. The interfacial GaOx layer suppresses dewetting of Au and enhances adhesion, ensuring mechanical robustness during deformation and reliability for real‐world applications including grilling ...
Younghyun Lee +8 more
wiley +1 more source
Conformational Switching of Proteins on Material Surfaces Enabled by Peptide‐Oriented Adsorption
Responsive biointerfaces could be achieved using conformationally responsive proteins; however, their interconversion can be lost upon surface adsorption. Herein, we demonstrate that the incorporation a Au binding peptide into calmodulin allows for binding control on Au wherein the protein retains conformational switching. This capability was confirmed
Sakthirupini Ramamurthy +7 more
wiley +1 more source
This study presents the technological progress in the deposition of diamond thin films on quartz crystal microbalance (QCM) sensors. The linear antenna microwave plasma chemical vapour deposition (CVD) technique effectively grows thin diamond films on ...
Tibor Izsák +10 more
doaj +1 more source
In this work, the processes of ice film disappearance under a stimulant convection conditions and absorption to ethanol vapor to ice film were monitored by a quartz crystal microbalance (QCM) technique.
Lei Yu +5 more
doaj +1 more source
Real-Time Detection of the Bacterial Biofilm Formation Stages Using QCM-Based Sensors [PDF]
Bacterial biofilms are a major cause of harm related to medical infections and biofouling. Thus, 80% of total infections are caused by biofilm-forming microorganisms.
Salazar Soler, Jorge +17 more
core +1 more source
Solution‐Processed Mn‐Doped 2d Perovskite Wavelength Shifters for Noble‐Liquid Photon Detection
Solution‐processed Mn2+‐doped PEA2PbBr4 two‐dimensional perovskite films are demonstrated as large‐area wavelength shifters for noble‐liquid photon detectors. Mn2+ incorporation introduces a broad emission band at ∼620 nm with a large Stokes shift, suppressing self‐absorption and matching SiPM sensitivity.
Elisabetta Colantoni +6 more
wiley +1 more source
The quartz crystal microbalance (QCM) measurement technique is utilized in a broad variety of scientific fields and applications, where surface and interfacial processes are relevant.
Rens J. Horst +3 more
doaj +1 more source
Array Formatting of the Heat-Transfer Method (HTM) for the Detection of Small Organic Molecules by Molecularly Imprinted Polymers [PDF]
In this work we present the first steps towards a molecularly imprinted polymer (MIP)-based biomimetic sensor array for the detection of small organic molecules via the heat-transfer method (HTM).
Peeters, Marloes +45 more
core +1 more source
Collagen II coatings support the formation of synovial fluid nanofilms, while collagen I coatings do not. Both bind recombinant equine lubricin similarly. These findings may help explain articular cartilage surface joint dysfunction, inform biomaterial design for synovial joint repair, and expand on lubricin‐based osteoarthritis therapies.
Diego R. Jaramillo Pinto +12 more
wiley +1 more source
A quartz crystal microbalance (QCM) biosensor with nanogram sensitivity has been constructed through a reasonable designing and biological processing of the piezoelectric quartz crystals.
Chunyan Yao, Ling Qu, Weiling Fu
doaj +1 more source

