Results 131 to 140 of about 222,384 (292)

Shielding resources for four common radiopharmaceuticals utilized for imaging and therapy: Tc‐99m, F‐18, I‐131, and Lu‐177

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Introduction The use of radioactive materials in the United States has been tightly regulated by the Nuclear Regulatory Commission and other entities for many decades. In 2015, however, the Joint Commission began to require hospital‐based nuclear medicine departments to conduct shielding designs and evaluations for radioactive material areas ...
Michael Oumano   +12 more
wiley   +1 more source

Assessment of a medical physics educational program for science teachers

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Introduction Medical physics is a fulfilling profession where physics is applied to advance human health. However, many are uninformed of the role of physicists in medicine, and students are unaware of this career pathway. This study presents a pilot 1‐year program for science teachers to learn about physics in medicine and share with students
Ashley J. Cetnar   +2 more
wiley   +1 more source

Comprehensive clinical evaluation of novel 4DCT‐based lung function imaging methods

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Methods have been developed that apply image processing to 4DCTs to generate 4DCT‐ventilation/perfusion lung imaging. Traditional methods for 4DCT‐ventilation rely on Hounsfield‐Unit (HU) density‐change methods and suffer from poor numerical robustness while not providing 4DCT‐perfusion data.
Ehsan Golkar   +6 more
wiley   +1 more source

GMDS concept for the further development of the structured quality report according to § 137 SGB V from 2007

open access: yesGMS Medizinische Informatik, Biometrie und Epidemiologie, 2006
In 2005 German hospitals for the first time published legally specified quality reports. A group of practitioners from the German health service analysed assessments of this public information tool and summarized demands on a further development of the ...
Bürgstein, H., Eckardt, J., Fischer, B.
doaj  

Novel CT radiomics models for the postoperative prediction of early recurrence of resectable pancreatic adenocarcinoma: A single‐center retrospective study in China

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose To assess the predictive capability of CT radiomics features for early recurrence (ER) of pancreatic ductal adenocarcinoma (PDAC). Methods Postoperative PDAC patients were retrospectively selected, all of whom had undergone preoperative CT imaging and surgery. Both patients with resectable or borderline‐resectable pancreatic cancer met
Xinze Du   +7 more
wiley   +1 more source

A Python package for fast GPU‐based proton pencil beam dose calculation

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Open‐source GPU‐based Monte Carlo (MC) proton dose calculation algorithms provide high speed and unparalleled accuracy but can be complex to integrate with new applications and remain slower than GPU‐based pencil beam (PB) methods, which sacrifice some physical accuracy for sub‐second plan calculation.
Mahasweta Bhattacharya   +4 more
wiley   +1 more source

Risk analysis of the Unity 1.5T MR‐Linac adapt‐to‐shape workflow

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background and Purpose The adapt‐to‐shape (ATS) workflow on the Unity MR‐Linac (Elekta AB, Stockholm, Sweden) allows for full replanning including recontouring and reoptimization5. Additional complexity to this workflow is added when the adaptation involves the use of MIM Maestro (MIM Software, Cleveland, OH) software in conjunction with ...
Jiayi Liang   +13 more
wiley   +1 more source

Professionalism skills education in medical physics residency: Current state and perceived importance

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose The purpose of this study was to collect data on current practices for teaching and assessing professionalism in CAMPEP‐accredited residency programs. Methods A survey of 21 questions was sent to 160 program directors (PDs) of CAMPEP‐accredited residency programs.
Anna Rodrigues   +5 more
wiley   +1 more source

Using deep learning generated CBCT contours for online dose assessment of prostate SABR treatments

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Prostate Stereotactic Ablative Body Radiotherapy (SABR) is an ultra‐hypofractionated treatment where small setup errors can lead to higher doses to organs at risk (OARs). Although bowel and bladder preparation protocols reduce inter‐fraction variability, inconsistent patient adherence still results in OAR variability.
Conor Sinclair Smith   +8 more
wiley   +1 more source

Home - About - Disclaimer - Privacy