Results 91 to 100 of about 155 (132)
Some of the next articles are maybe not open access.

Experimental investigation of the performance of an R1270/CO2 cascade refrigerant system

International Journal of Refrigeration, 2020
Abstract Herein, we proposed a cascade refrigerant system with R1270 and carbon dioxide refrigerants. The natural refrigerant R1270 was adopted in the high-temperature circuit to replace NH3 and R290. A prototype cascade refrigerant system with two semi-hermetic piston compressors was manufactured, and its performance was investigated experimentally.
Yeqiang Zhang   +5 more
openaire   +1 more source

Convective condensation of R600a, R290, R1270 and their zeotropic binary mixtures in horizontal tubes

International Journal of Refrigeration, 2021
Abstract The present paper concerns an experimental investigation about the heat transfer coefficient during convective condensation of hydrocarbons and their zeotropic mixtures. Experiments were performed in a horizontal smooth channel, with internal diameter of 9.43 mm for R600a, R290, R1270, R600a/R290 (70/30 molar fraction) and R600a/R1270 (75/25
Tiago Augusto Moreira   +2 more
openaire   +1 more source

Numerical study of the flow of R1270-based nanorefrigerants in a circular tube subject to uniform heat flux

open access: yesMicro and Nano Letters, 2018
In this work, turbulent convective heat transfer of propylene (R1270)‐based nanorefrigerant in a circular tube with a uniform heat flux of 20 kW/m 2 is numerically investigated using different types of nanoparticles namely Al 2 O 3
Ahmed OUADHA, Mohammed Zohud
exaly   +2 more sources

Experimental performance study of a small wall room air conditioner retrofitted with R290 and R1270

International Journal of Refrigeration, 2012
An original R22 wall room air conditioner with a cooling capacity of 2.4 kW and energy efficiency ratio (EER) of 3.2 is retrofitted with a compressor of a 20% larger displacement to charge R290 and R1270 for performance experiments. The results show that for R1270, only adopting a same kind mineral lubricant of higher viscosity would supply 2.4% higher
J H Wu
exaly   +2 more sources

Thermodynamic performance enhancement of booster assisted ejector expansion refrigeration systems with R1270/CuO nano-refrigerant

Energy Conversion and Management, 2022
Ejector expansion refrigeration systems have gained prominence in the refrigeration sector, providing much better thermodynamic performance than conventional refrigeration systems. The present work aims to improve the thermodynamic performance of a booster assisted ejector expansion vapour compression refrigeration system with constant area mixing ...
Ilhan Tekin Öztürk
exaly   +3 more sources

Performance of a Split-Type Air Conditioner with Natural Refrigerant R1270 to Replace R22

Advanced Materials Research, 2011
A natural and environment friendly refrigerant propylene (R1270) is proposed as a substitute of R22 in the residential air conditioner. The experiments on the cooling performance of the air conditioner with R1270 and R22 were respectively conducted on an existing enthalpy potential bench, during the degree of superheating keep constant and refrigerant ...
Jian Bo Chen
exaly   +2 more sources

Performance of R290 and R1270 for R22 applications with evaporator and condenser temperature variation

Journal of Mechanical Science and Technology, 2008
In this study, therma l performance of two hydrocarbon refrigerants of R290 and R1270 was measured in an attempt to substitute R22. They wer tested in a heat pump bench tester of 1 ton capacity with a hermetic rotary compressor. Water and water/glycol mixture were employed as the secondary heat transfer fluids in the test bench.
Ki-Jung Park, Dongsoo Jung
openaire   +1 more source