Results 141 to 150 of about 724 (168)
Some of the next articles are maybe not open access.

Derived thermodynamic design data for heat pump systems operating on R1270

Heat Recovery Systems and CHP, 1991
Abstract Theoretical Rankine coefficients of performance and the compression ratios have been presented for heat pump systems operating on R1270. These values are listed in tabular form for temperature lifts of 5–75°C and condensing temperatures of 12–90°C in one degree increments.
M.A.R. Eisa   +2 more
openaire   +1 more source

Performance of R290 and R1270 for R22 applications with evaporator and condenser temperature variation

Journal of Mechanical Science and Technology, 2008
In this study, therma l performance of two hydrocarbon refrigerants of R290 and R1270 was measured in an attempt to substitute R22. They wer tested in a heat pump bench tester of 1 ton capacity with a hermetic rotary compressor. Water and water/glycol mixture were employed as the secondary heat transfer fluids in the test bench.
Ki-Jung Park, Dongsoo Jung
openaire   +1 more source

Performance of a Split-Type Air Conditioner with Natural Refrigerant R1270 to Replace R22

Advanced Materials Research, 2011
A natural and environment friendly refrigerant propylene (R1270) is proposed as a substitute of R22 in the residential air conditioner. The experiments on the cooling performance of the air conditioner with R1270 and R22 were respectively conducted on an existing enthalpy potential bench, during the degree of superheating keep constant and refrigerant ...
Jian Bo Chen   +3 more
openaire   +1 more source

Thermodynamic analysis of a novel dual-temperature air-source heat pump combined ejector with zeotropic mixture R1270/R600a

Energy Conversion and Management, 2020
Abstract This study presents a novel dual-temperature air-source heat pump system with an ejector using zeotropic mixture R1270/R600a. The system provides a high-temperature heat source (around 60 °C hot water) and low-temperature heat source (around 35 °C hot water) respectively. The system improves its performance via the application of an ejector.
Jian Liu, Zhang Lin
openaire   +1 more source

Performance of Air Cooled Heat Pump Air Conditioner with Natural Refrigerant R1270 and R290 to Replace R22

Advanced Materials Research, 2011
A natural and environment friendly refrigerant propylene and propane are proposed as the substitute of R22 in air conditioner. The experiments were respectively conducted on an existing enthalpy potential lab. Refrigerant charge was held at the constant superheat condition.
Jian Bo Chen, He Li, Ling Xi
openaire   +1 more source

The Experiment on System Performance Comparing Analysis and Displacement between R1270 and R22

Applied Mechanics and Materials, 2015
The refrigeration circle performance of air conditioning comparing analysis and displacement between R1270 and R22 is studied in this paper. In addition, the system performance optimization of R1270 refrigeration circle is discussed.The experimental results show that the smaller tube diameter of heat exchanger for R1270 system is easy to improve the ...
openaire   +1 more source

Experimental study of performance AC split retrofitting R32 to R1270

AIP Conference Proceedings, 2023
null Ridwan   +3 more
openaire   +1 more source