Results 41 to 50 of about 155 (132)
Refrigerator technology continues to develop towards a better and more efficient direction. Refrigerator must be given a touch of innovation to get the best performance. This study aims to obtain data on the performance of refrigerators with double pipe heat exchanger innovation and variations in the length of the capillary tube.
openaire +1 more source
R1270 and R290 are alternative refrigerants with great potential. In this study, the influence of the refrigerant charge on the performance of the heat-pump water heater with R1270 and R290, the temperature distribution of the heat transfer fluids in the
Ju Fujun +5 more
doaj
In light of the low performance of the basic CO2 transcritical refrigeration cycle, this study explores several CO2-hydrocarbon blends to enhance the Coefficient of Performance (COP) and, consequently, minimise the cycle's electrical power consumption. Based on a single-stage cycle with IHX four blends of carbon dioxide/propylene (CO2/R1270) and carbon
R. Larrondo-Sancho +2 more
openaire +1 more source
This study investigates the impact of condensation temperature on the thermodynamics of Rankine cycles for LNG cold energy recovery using seawater as heat source.
Qiang Liu, Jian Song, Yuanyuan Duan
doaj +1 more source
Theoretical Study on Novel Refrigerant Mixture R1270/R152a/R13I1
A new refrigerant mixture,R1270/R152a/R13I1,is proposed as a substitute for R22 in this paper.The thermophysical properties of this environment-friendly mixture and its refrigeration system performance are theoretically analyzed with the software Refprop
冯永斌, 晏刚, 钱文波
doaj
Experimental study on alternative performance of R32/R1270 in low temperature heating heat pump
The effect of refrigerant charge on the system performance of quasi-two-stage compression heat pump (QCHP) with replacement refrigerant of R32/R1270 (15/85 wt.%) (B for short) for district heating was studied under nominal conditions based on the self-designed QCHP test system and the feasibility of replacing R22 with B was discussed under variable ...
Fujun Ju +8 more
openaire +1 more source
Implementing the Montreal Protocol has limited the use of conventional refrigerants and has led industries to find optimal or economical eco-friendly refrigerants to reduce environmental hazards.
Sachin Kumar +2 more
doaj +1 more source
A Study on the Simulation and Experiment of Evaporative Condensers in an R744 Air Conditioning System. [PDF]
Dang T, Nguyen H.
europepmc +1 more source
The study introduces an innovative three-stage nested power generation system that enables the cascading utilization of LNG cold energy. It makes the most of wasted energy by using ship jacket cooling water (JCW) and exhaust gas (EG) as heat sources, a ...
Zhenzhen Chen +4 more
doaj +1 more source
Soft Tissue Benign Hand Masses in the First Web Space: A Retrospective Case Series. [PDF]
Saleh ES +5 more
europepmc +1 more source

