Results 151 to 160 of about 126,690 (308)

Isovolumic relaxation strain imaging is an accurate and sensitive approach for detection of active diastolic dysfunction: A preclinical study

open access: yesAnimal Models and Experimental Medicine, EarlyView.
A modified approach was developed to accurately identify the isovolumetric relaxation time (IVRT) using an apical three‐chamber view. Compared with conventional echocardiography, isovolumic relaxation strain imaging (IVSI) helps to detect the earlier alternations of diastolic function in transverse aortic constriction (TAC) mice.
Jingjing Liang   +3 more
wiley   +1 more source

Wireless blood pressure sensor implantation in sheep: A detailed technique

open access: yesAnimal Models and Experimental Medicine, EarlyView.
Twelve adult sheep underwent wireless blood pressure sensor implantation. The procedure lasted an average of 36 min, with mean systolic and diastolic blood pressures of 93 ± 6 and 65 ± 5 mmHg, respectively. This rapid, minimally invasive protocol is a powerful platform for cardiovascular device development.
David Santer   +10 more
wiley   +1 more source

Performing radial artery puncture

open access: yesTurk Kardiyoloji Dernegi Arsivi-Archives of the Turkish Society of Cardiology, 2014
Veysel Kutay Vurgun, Başar Candemir
openaire   +3 more sources

A high‐fat diet with vitamin D and propylthiouracil produces a pro‐atherogenic phenotype in rats

open access: yesAnimal Models and Experimental Medicine, EarlyView.
Male Sprague–Dawley rats received a cholesterol‐rich high‐fat diet supplemented with vitamin D and propylthiouracil for 11 weeks. The model induced dyslipidemia (increased total cholesterol/low‐density lipoprotein, decreased triglycerides), inflammation (increased interleukin‐6 and serum amyloid A), hypercalcemia, and reduced circulating endothelial ...
Angélique Lewies   +3 more
wiley   +1 more source

Morphological and morphometric aspects of the equine aortic valve: New insights for comparative studies in mammals

open access: yesThe Anatomical Record, EarlyView.
Abstract New data on the equine aortic valve obtained using advanced techniques is especially important given the greater availability of animal models for translational research. Here we characterized the morphological and morphometric aspects of the equine aortic valve from 60 healthy hearts collected at equine abattoirs.
Vitor Pires Pereira   +3 more
wiley   +1 more source

A contribution to the anatomy of two rare cetacean species: The hourglass dolphin (Cephalorhynchus cruciger) and the spectacled porpoise (Phocoena dioptrica)

open access: yesThe Anatomical Record, EarlyView.
Abstract The anatomical description of the hourglass dolphin (Cephalorhynchus cruciger) and the spectacled porpoise (Phocoena dioptrica) remains largely unexplored, due to limited specimen availability and preservation challenges. This study employed digital imaging techniques, conventional histology, and computed tomography to provide visualization of
Jean‐Marie Graïc   +26 more
wiley   +1 more source

Trabecular bone ontogeny of the human talus

open access: yesThe Anatomical Record, EarlyView.
Abstract Studies of trabecular ontogeny may provide insight into the factors that drive healthy bone development. There is a growing understanding of how the juvenile skeleton responds to these influences; however, gaps in our knowledge remain. This study aims to identify ontogenetic trabecular patterns and regional changes during development within ...
Rebecca A. G. Reid   +2 more
wiley   +1 more source

The skeleton of the green Iguana iguana (Squamata: Iguanidae) and its intraspecific morphological variation

open access: yesThe Anatomical Record, EarlyView.
Abstract The green iguana (Iguana iguana) is an iguanine lizard with herbivorous and arboreal habits, whose distribution spans through South America, Central America to the south of North America. Although the genus Iguana is well‐known, the species still lacks a comprehensive and up‐to‐date anatomical study, particularly addressing the axial skeleton,
Vieno Rosa   +2 more
wiley   +1 more source

A critical reappraisal of the carotid sinus and carotid bulb: Distinguishing neurohistological function from vascular geometry

open access: yesThe Anatomical Record, EarlyView.
This review redefines the carotid bulb (CB) as a variable geometric dilation shaped by hemodynamics and the carotid sinus (CS) as a conserved neurohistological baroreceptor field. Distinguishing these entities clarifies a century of anatomical confusion and links geometry, neurohistology, and clinical interpretation within a unified framework ...
Răzvan Costin Tudose   +2 more
wiley   +1 more source

Home - About - Disclaimer - Privacy