Results 81 to 90 of about 1,091,668 (300)

Single‐Dose TACE‐Like Injection of Sustained‐Release Panobinostat/IL‐12 Polymeric Microparticles is Effective in Preclinical Liver Cancer Models

open access: yesAdvanced Science, EarlyView.
A novel PLGA/PBAE polymer microparticle platform revolutionizes intermediate‐stage liver cancer treatment by co‐delivering panobinostat and IL‐12 via a single TACE‐like injection. This sustained‐release system overcomes tumor immunosuppression, triggers robust innate and adaptive immune responses, and establishes tertiary lymphoid structures ...
Hongzhe Yu   +7 more
wiley   +1 more source

75. Endoscopic radial artery harvest reduces forearm complications when compared to conventional methods: A pooled Analysis

open access: yesJournal of the Saudi Heart Association, 2015
Impetus on total arterial revascularization has led to increased use of the radial artery as a conduit for coronary artery bypass grafting. The radial artery conduit is being increasingly as alternative to saphenous vein as conduit.
Salah Eldien Altarabsheh   +4 more
doaj   +1 more source

Histopathologic changes of the radial artery wall secondary to transradial catheterization

open access: yes, 2009
Cezar S Staniloae1, Kanika P Mody1, Kintur Sanghvi1, Catalin Mindrescu1, John T Coppola1, Cristina R Antonescu2, Sanjay Shah3, Tejas Patel31Saint Vincent’s Hospital Manhattan, New York, NY, USA; 2Memorial Sloan-Kettering Cancer Center, New York,
Kintur Sanghvi   +4 more
core  

The comparison between intra-radial and intra-brachial artery BPs.

open access: yes, 2014
BPr-b: the difference between intra-radial and intra-brachial artery BP.*: compared with intra-radial ...
Juxiang Li (508673)   +7 more
core   +1 more source

Increased Disarray of Extracellular Matrix Collagen‐I Fiber Network and Compromised Biomechanics in Aortae From Marfan‐Syndrome Mice Assessed Through Combined Opto‐Biomechatronics

open access: yesAdvanced Science, EarlyView.
Combined structure‐function assessment in aortic rings from Marfan mice using MechaMorph Opto‐Biomechatronics technology relates increased elasticity (stiffness) and dynamic viscosity and less ordered extracellular matrix 3D‐structure (collagen) as potential causes for impaired Windkessel function and compromised haemodynamics in Marfan's syndrome ...
Dominik Schneidereit   +10 more
wiley   +1 more source

Systematic evaluation on application effect of spiral and balloon radial artery compression hemostat

open access: yesHuli yanjiu, 2019
Objective:To systematically evaluate the effect of spiral and balloon radial artery compression hemostats after transradial artery puncture.Methods:Randomized controlled trials(RCTs)on the application of spiral and balloon radial artery compression ...
张淑   +4 more
doaj  

A modified technique for radial artery access: how interventional radiologists can optimise the cardiologists’ technique to suite their procedures

open access: yesCVIR Endovascular
Background This is a single-centre prospective observational study examining radial access in 62 Prostatic Artery Embolisation (PAE) procedures. Evaluation of left radial artery diameter using high frequency ultrasound before and after administration of ...
Zaid Aldin   +9 more
doaj   +1 more source

Ruptured pseudoaneurysm of the radial artery

open access: yesBMJ Case Reports, 2009
A 40-year-old man presented with a progressively increasing swelling over the ventral aspect of the right wrist of 23 days duration following a laceration. The swelling was soft, pulsatile and was intermittently bleeding, with poor distal capillary filling and cold distal extremity. Clinically it was diagnosed as pseudoaneurysm of the radial artery and
Subhajeet, Dey   +2 more
openaire   +3 more sources

Longitudinal Multifrequency MR Elastography Reveals Biomechanical Signatures of Progression in a Translational Liver Tumor Model

open access: yesAdvanced Science, EarlyView.
Longitudinal multifrequency magnetic resonance elastography (mMRE) performed on a clinical 3 Tesla magnetic resonance imaging system reveals early biomechanical alterations during liver tumor progression in a translational VX2 model. Changes in tumor stiffness and viscosity precede diffusion‐related alterations and are associated with extracellular ...
Justus Ramtke   +20 more
wiley   +1 more source

Methods for increasing distal radial artery diameter

open access: yes, 2023
OBJECTIVE: Our study aimed to find the maximum rate of increase in distal radial artery size. PATIENTS AND METHODS: Diameter measurements were obtained on transverse and sagittal sections of the artery with a high-frequency linear transducer (Philips ...
Demırkıran, Aykut, Aydın, Cihan
core   +1 more source

Home - About - Disclaimer - Privacy