Results 111 to 120 of about 3,736,664 (260)
Radiation Monitoring of Workplace Principles of Radiation Monitoring (II)
MINAMI, Kenkaro, OSHINO, Masao
openaire +3 more sources
Initial experience with an 11 MeV self-shielded medical cyclotron on operation and radiation safety
A self-shielded medical cyclotron (11 MeV) was commissioned at our center, to produce positron emitters, namely, 18 F, 15 O, 13 N and 11 C for positron emission tomography (PET) imaging.
Pant G, Senthamizhchelvan S
doaj
Amphoteric Cu‐Doping Leading to High Thermoelectric Performance in p‐Type Bismuth Antimony Telluride
This study shows that Cu plays two opposite roles in p‐type Bi0.5Sb1.5Te3 depending on the processing route. Under thermodynamic‐equilibrium bulk‐synthesis, Cu mainly occupies cation sites, increases hole concentration, preserves mobility, and slightly reduces lattice heat transport. The best‐performing composition among the investigated series reaches
Moritz Thiem +15 more
wiley +1 more source
Environmental radiation surveillance in Kansas, July 1991-June 1992
Prepared by Environmental Radiation and Emergency Preparedness Section, Radiation Control Program, Bureau of Air and Radiation. "Winter 1992."This publication reports the results of the environmental radiation surveillance programs conducted ...
Kansas Bureau of Air and Radiation. Environmental Radiation and Emergency Preparedness Section
core +1 more source
A removable sacrificial polymer layer engineers the thermal boundary condition during nanosecond laser ablation of PET, suppressing heat‐affected‐zone formation without relying on costly ultrafast lasers. This strategy enables deep, high‐aspect‐ratio trenches with no detectable heat‐affected zone, templating silver‐filled mesh electrodes with record ...
Mehdi Zarei +3 more
wiley +1 more source
Nitride MXenes remain constrained by a persistent gap between computational prediction and experimental realization. This Review identifies the thermodynamic, kinetic, and chemical barriers limiting their synthesis, critically evaluates emerging fabrication routes, and proposes a multidimensional computational‐experimental framework to accelerate the ...
Naresh Varnakavi, Masoud Soroush
wiley +1 more source
The article presents the issues of radiation monitoring management, done by the Russian Federation subject territories for the assessment of population radiation safety conditions and filling the radiation hygienic passport of the territory. An algorithm
A. N. Barkovsky, N. K. Baryshkov
doaj
University of California Radiation Laboratory Report UCRL-627
Quarterly summary report of studies conducted through the Radiation Laboratory, University of California.
Lawrence Radiation Laboratory
core
Defect‐free transfer principles enable scalable fabrication of 15 µm‐thin garnet‐based hybrid solid electrolytes. Hansen solubility parameters correlate interfacial compatibility with coating, transfer, and impregnation behavior, guiding rational selection of slurry/substrate, binder/substrate, and binder/polymer electrolyte combinations.
Seul Gi Chu +8 more
wiley +1 more source
University of California Radiation Laboratory Report UCRL-2512
The following report is a general monthly progress report conducted by the radiation laboratory of the University of California discussing experimental physics, theoretical physics, the MTA target physics program, accelerator construction and operation ...
Lawrence Radiation Laboratory
core

