Results 161 to 170 of about 4,225,714 (422)
Acoustic emissions during direct laser interference patterning are shown to strongly correlate with surface texture depth. By implementing a closed‐loop control system utilizing acoustic feedback, consistent microstructures with uniform depth are achieved despite laser power fluctuations.
Tobias Steege+4 more
wiley +1 more source
Human Factors Ground Test Assessment and Protocol Development for Space Radiation Protection Concepts [PDF]
Human factors evaluations and procedures were developed in a series of ground tests in order to assess novel radiation protection concepts developed by industry leaders in aerospace.
Clowdsley, Martha+2 more
core +1 more source
Recent Progress on 2D‐Material‐Based Smart Textiles: Materials, Methods, and Multifunctionality
Advancements in 2D‐material‐integrated smart textiles are reviewed, with a focus on materials, fabrication methods, and multifunctional applications, including energy harvesting, monitoring, EMI shielding, energy storage, and thermal management. The discussion addresses key challenges and provides insights into the future development of next‐generation
Yong Choi+5 more
wiley +1 more source
Survey on data management in radiation protection research [PDF]
The importance of datasharing is of increasing concern to funding bodies and institutions. With some prescience, the radiobiology community has established data sharing infrastructures over the last two decades, including STORE; however, the utilisation of these databases is disappointing.
arxiv
Radiation protection guidelines for space missions [PDF]
NASA's current radiation protection guidelines date from 1970, when the career limit was set at 400 rem. Today, using the same approach, but with the current risk estimates, a considerably lower career limit would obtain. Also, there is considerably more
Fry, R. J. M., Nachtwey, D. S.
core +1 more source
Laboratory protocols for producing thin‐film pH electrodes for sterilized single‐use technologies have been successfully developed into a semiautomated workflow, with higher throughput and precision of membrane thickness. Accuracies are within 0.05 pH units versus ground truth, and uncertainty analysis reveals the largest sources of error to be derived
Bingyuan Zhao+4 more
wiley +1 more source
Measurement Performance of Electronic Radon Monitors
The measurement performance and characteristics of electronic radon monitors with respect to radiological and environmental parameters are investigated. The study includes a sample of 14 different types of devices from nine manufacturers. The devices are
Thomas R. Beck+3 more
doaj +1 more source
Radiation protection for manned space activities [PDF]
The Earth's natural radiation environment poses a hazard to manned space activities directly through biological effects and indirectly through effects on materials and electronics.
Jordan, T. M.
core +1 more source