Effects of cardiac motion on dose distribution during stereotactic arrhythmia radioablation treatment: A simulation and phantom study

open access: yesJournal of Applied Clinical Medical Physics, Volume 26, Issue 5, May 2025.
Abstract Purpose Cardiac motion may degrade dose distribution during stereotactic arrhythmia radioablation using the CyberKnife system, a robotic radiosurgery system. This study evaluated the dose distribution changes using a self‐made cardiac dynamic platform that mimics cardiac motion. Methods The cardiac dynamic platform was operated with amplitudes
Takayuki Miyachi   +6 more
wiley   +1 more source

Towards 3D printed multifunctional immobilization for proton therapy: initial materials characterization [PDF]

open access: yes, 2016
Purpose: 3D printing technology is investigated for the purpose of patient immobilization during proton therapy. It potentially enables a merge of patient immobilization, bolus range shifting, and other functions into one single patient-speci c structure.
Ahn   +44 more
core   +2 more sources

Auto-development issue in quality assurance of biological X-ray irradiator using Gafchromic EBT3 film

open access: yesResults in Physics, 2017
Radiochromic films are convenient dosimeters for quality assurance of biological X-ray irradiators. However, their calibration curves (optical density vs. radiation dose) can have relatively short lifespans due to non-catalytic auto-development.
P.M. Chan   +4 more
doaj  

Evaluation of a complementary metal oxide semiconductor detector as a tool for stereotactic body radiotherapy plan quality assurance

open access: yesPhysics and Imaging in Radiation Oncology, 2023
Background and purpose: A sub-mm resolution Complementary Metal Oxide Semiconductor sensor has been developed for stereotactic radiotherapy quality assurance.
Chris J. Stepanek   +2 more
doaj  

High sensitivity radiochromic film dose comparisons [PDF]

open access: yesPhysics in Medicine and Biology, 2002
This short note investigates the dose characteristics of a relatively new high sensitivity radiochromic film (Gafchromic HS) and compares dose and energy response to various Gafchromic film types and radiographic (EDR-2) film. The original MD-55-1 and two improved sensitivity films, MD-55-2 and HS film, were investigated for energy and dose response ...
Martin J Butson   +4 more
openaire   +2 more sources

In vivo transit dosimetry methodology for whole breast intensity modulated radiation therapy

open access: yesJournal of Applied Clinical Medical Physics, Volume 26, Issue 5, May 2025.
Abstract Background In vivo transit dosimetry using an electronic portal imaging device (EPID‐IVTD) is an important tool for verifying the accuracy of radiation therapy treatments. Despite its potential, the implementation of EPID‐IVTD in breast intensity modulated radiation therapy (IMRT) treatments has not yet been standardized, limiting its clinical
Lucia Zirone   +8 more
wiley   +1 more source

Results of a Geant4 benchmarking study for bio‐medical applications, performed with the G4‐Med system

open access: yesMedical Physics, Volume 52, Issue 5, Page 2707-2761, May 2025.
Abstract Background Geant4, a Monte Carlo Simulation Toolkit extensively used in bio‐medical physics, is in continuous evolution to include newest research findings to improve its accuracy and to respond to the evolving needs of a very diverse user community.
Pedro Arce   +57 more
wiley   +1 more source

Evaluation of a synthetic single-crystal diamond detector for relative dosimetry on the Leksell Gamma Knife Perfexion radiosurgery system [PDF]

open access: yes, 2015
Purpose: To evaluate the new commercial PTW-60019 synthetic single-crystal microDiamond detector (PTW, Freiburg, Germany) for relative dosimetry measurements on a clinical Leksell Gamma Knife Perfexion radiosurgery system. Methods: Detector output ratios
Alfonso   +47 more
core   +1 more source

Quality assurance procedures based on dosimetric, gamma analysis as a fast reliable tool for commissioning brachytherapy treatment planning systems

open access: yesRadiology and Oncology, 2017
Fast and easily repeatable methods for commissioning procedures for brachytherapy (BT) treatment planning systems (TPS) are needed. Radiochromic film dosimetry with gamma analysis is widely used in external beam quality assurance (QA) procedures and ...
Zwierzchowski Grzegorz   +2 more
doaj   +1 more source