Results 181 to 190 of about 4,735 (211)
Some of the next articles are maybe not open access.

Spatial resolution of a stacked radiochromic film dosimeter

Radiotherapy and Oncology, 2001
The spatial resolution of stacked radiochromic film dosimeters, which have increased sensitivity from a single layer radiochromic film detector, has been studied.A 5-layer film which can easily be constructed provided a 4.3-times increase in sensitivity over a single layer film at 670 nm readout wavelength which meant that doses as low as 0.6 Gy could ...
M J, Butson, T, Cheung, P K, Yu
openaire   +2 more sources

Assessment of concomitant testicular dose with radiochromic film

Australasian Physical & Engineering Sciences in Medicine, 2013
To assess the suitability of EBT2 and XRQA2 Gafchromic film for measuring low doses in the periphery of treatment fields, and to measure the accumulative concomitant dose to the contralateral testis resulting from CT imaging, pre-treatment imaging (CBCT) and seminoma radiotherapy with and without gonadal shielding.
Katherine, Fricker   +2 more
openaire   +2 more sources

A universal dose–response curve for radiochromic films

Medical Physics, 2015
Purpose:This paper presents a model for dose–response curves of radiochromic films. It is based on a modified version of single‐hit model to take into account the growth experienced by lithium salt of pentacosa‐10,12‐diynoic acid polymers after irradiation.Methods:Polymer growth in radiochromic films is a critical phenomenon that can be properly ...
J A, Martín-Viera Cueto   +5 more
openaire   +2 more sources

Characteristics of Gafchromic® XR‐RV2 radiochromic film

Medical Physics, 2009
Gafchromic® XR‐RV2 is a revised version of the obsolete Gafchromic® XR‐R‐type radiochromic film. This article investigates the dose response, energy response, postexposure growth, and polarizing effects of this film after exposure to ionizing radiation in the diagnostic energy range. The effect of bit depth on scanning was also investigated. Films were
Andrew, Blair, Juergen, Meyer
openaire   +2 more sources

A prototype quantitative film scanner for radiochromic film dosimetry.

Medical physics, 2008
We have developed a high resolution, quantitative, two-dimensional optical film scanner for use with a commercial high sensitivity radiochromic film (RCF) for measuring single fraction external-beam radiotherapy dose distributions. The film scanner was designed to eliminate artifacts commonly observed in RCF dosimetry. The scanner employed a stationary
Manisha K, Ranade   +5 more
openaire   +1 more source

Lithium-film ceramics for solid-state lithionic devices

Nature Reviews Materials, 2020
Yuntong Zhu   +2 more
exaly  

From Protein Film Electrochemistry to Nanoconfined Enzyme Cascades and the Electrochemical Leaf

Chemical Reviews, 2023
Fraser A Armstrong   +2 more
exaly  

Thin-film ferroelectric materials and their applications

Nature Reviews Materials, 2016
Lane Martin, Andrew M Rappe
exaly  

Home - About - Disclaimer - Privacy