Results 61 to 70 of about 2,171,676 (258)

Measurement of the Charge Collection Efficiency after Heavy Non-Uniform Irradiation in BaBar Silicon Detectors

open access: yes, 2005
We have investigated the depletion voltage changes, the leakage current increase and the charge collection efficiency of a silicon microstrip detector identical to those used in the inner layers of the BaBar Silicon Vertex Tracker (SVT) after heavy non ...
/INFN, Pisa /Pisa U. /SLAC   +12 more
core   +4 more sources

Implementation of an intraoperative electron radiotherapy in vivo dosimetry program [PDF]

open access: yes, 2016
Background: Intraoperative electron radiotherapy (IOERT) is a highly selective radiotherapy technique which aims to treat restricted anatomic volumes during oncological surgery and is now the subject of intense re-evaluation.
Boldó, Enrique   +5 more
core   +3 more sources

Energy dependence of the GAFCHROMIC LD‐V1 in the diagnostic radiographic modalities

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract The GAFCHROMIC LD‐V1 radiochromic film is widely used in dosimetry because it can provide high‐resolution two‐dimensional dose distributions without processing. This study aimed to evaluate the response characteristics at different effective energies, from the low‐energy range of mammography to the high‐energy range of computed tomography. Net
Tatsuhiro Gotanda   +9 more
wiley   +1 more source

Dosimetric evaluation and clinical application of collimated apertures with proton beam line scanning in stereotactic radiotherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Stereotactic radiotherapy (SRT) is a highly effective treatment with precision for small, localized lesions. Proton therapy, characterized by the Bragg peak, offers superior dose conformity compared to photon‐based approaches. However, challenges remain in minimizing lateral penumbra and optimizing dose delivery, particularly for small
Chen‐Yu Chou   +3 more
wiley   +1 more source

Comprehensive end‐to‐end dosimetry audit for stereotactic body radiotherapy in spine, lung, and soft tissue

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose To create and conduct a comprehensive onsite end‐to‐end dosimetry audit to assess treatment accuracy of spine, lung, and soft tissue Stereotactic Body Radiotherapy (SBRT) across Australian and New Zealand (ANZ) radiotherapy centers. Methods The Australian Clinical Dosimetry Service (ACDS) anthropomorphic thorax phantom underwent a CT ...
Maddison Shaw   +8 more
wiley   +1 more source

Development of a new Thomson parabola spectrometer for analysis of laser accelerated ions [PDF]

open access: yes, 2020
This thesis details my work on developing a new Thomson parabola spectrometer for use at the SCARLET Laser Facility at The Ohio State University. The SCARLET laser facility is a 300 TW laser reaching peak intensities exceeding 10 21 W/cm 2 .
Winter, Connor
core  

Patients skin dose measurements during interventional radiological examinations using Gafchromic XR-RV3 FILM

open access: yesРадиационная гигиена, 2020
This work is devoted to the assessment of the absorbed dose in the skin of patients undergoing interventional radiological examinations. There is a probability of deterministic effects in the skin of patients due to high doses of radiation during this ...
Svetlana S. Sarycheva
doaj   +1 more source

The Multigaussian method: a new approach to mitigating spatial heterogeneities with multichannel radiochromic film dosimetry [PDF]

open access: yesPhysics in Medicine and Biology, 2018
The main objective of multichannel radiochromic film dosimetry methods is to correct, or at least mitigate, spatial heterogeneities in the film-scanner response, especially variations in the active layer thickness.
Ignasi Mendez   +3 more
semanticscholar   +1 more source

Numerical Modeling of Isochoric Heating Experiments Using the Troll Code in the Warm Dense Matter Regime

open access: yesContributions to Plasma Physics, EarlyView.
ABSTRACT Experiments of isochoric heating by protons of solid material were recently performed at LULI laser facilities. In these experiments, protons, produced from target normal sheath acceleration (TNSA) of Au foil with the PICO2000 laser, deposit their energy into an aluminum or copper foil initially at room temperature and solid density.
Sébastien Rassou   +9 more
wiley   +1 more source

Numerical Simulation of magnetized jet creation using a hollow ring of laser beams

open access: yes, 2018
Three dimensional FLASH magneto-hydrodynamics(MHD) modeling is carried out to interpret the OMEGA laser experiments of strongly magnetized, highly collimated jets driven by a ring of 20 OMEGA beams.
Birkel, A.   +13 more
core   +1 more source

Home - About - Disclaimer - Privacy