Ultraviolet radiometry with synchrotron radiation and cryogenic radiometry
Applied Optics, 1999The combination of a cryogenic radiometer and synchrotron radiation enables detector scale realization in spectral regions that are otherwise difficult to access. Cryogenic radiometry is the most accurate primary detector-based standard available to date, and synchrotron radiation gives a unique broadband and continuous spectrum that extends from x ray
P S, Shaw +8 more
openaire +2 more sources
Applied Optics, 1973
When the absolute value X = ?Xmicro(micro).dmicro of incident radiation cannot be obtained from the output V = ?Xmicro(micro) R(x)(micro) dmicroof a selective instrument, with nonuniform responsivity R(x)(micro) = V(micro)(micro)/X(micro)(micro), because the incident distribution X(micro),(micro) is not known, recourse is had to various normalization ...
openaire +2 more sources
When the absolute value X = ?Xmicro(micro).dmicro of incident radiation cannot be obtained from the output V = ?Xmicro(micro) R(x)(micro) dmicroof a selective instrument, with nonuniform responsivity R(x)(micro) = V(micro)(micro)/X(micro)(micro), because the incident distribution X(micro),(micro) is not known, recourse is had to various normalization ...
openaire +2 more sources
Review of Scientific Instruments, 1971
An ir radiometer utilizing a Golay cell was constructed to measure heat production in excised muscle preparations near room temperature. This radiometer resolves temperature changes of 1 mdeg on surface areas of several square millimeters with a lag time constant of a few milliseconds.
openaire +2 more sources
An ir radiometer utilizing a Golay cell was constructed to measure heat production in excised muscle preparations near room temperature. This radiometer resolves temperature changes of 1 mdeg on surface areas of several square millimeters with a lag time constant of a few milliseconds.
openaire +2 more sources
Journal of the Optical Society of America, 1968
The basic laws of photometry are derived from the theory of partial coherence by considering a generalized form of the Van Cittert–Zernike theorem.
openaire +1 more source
The basic laws of photometry are derived from the theory of partial coherence by considering a generalized form of the Van Cittert–Zernike theorem.
openaire +1 more source
Photothermal radiometry methods in materials science and applied chemical research
Journal of Applied Physics, 2022Polina Fomina +2 more
exaly