Results 151 to 160 of about 29,895 (213)
Emerging paradigms in microwave imaging technology for biomedical applications: unleashing the power of artificial intelligence. [PDF]
Khalid N +3 more
europepmc +1 more source
Mid-infrared spectroscopy on a fiber tip for molecular monitoring. [PDF]
Lee TA, Xiao Z, Burghoff DP, Hutter T.
europepmc +1 more source
OH* 3D Concentration Measurement of Non-Axisymmetric Flame via Near-Ultraviolet Volumetric Emission Tomography. [PDF]
Ma J +5 more
europepmc +1 more source
Thermal Imaging for Teaching Materials Chemistry: Phase Change Materials toward Energy Transition. [PDF]
de Cabo-Rodríguez C +7 more
europepmc +1 more source
Key results and possible future endeavors of the Russian health studies program. [PDF]
Napier BA.
europepmc +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Review of Scientific Instruments, 1971
An ir radiometer utilizing a Golay cell was constructed to measure heat production in excised muscle preparations near room temperature. This radiometer resolves temperature changes of 1 mdeg on surface areas of several square millimeters with a lag time constant of a few milliseconds.
openaire +2 more sources
An ir radiometer utilizing a Golay cell was constructed to measure heat production in excised muscle preparations near room temperature. This radiometer resolves temperature changes of 1 mdeg on surface areas of several square millimeters with a lag time constant of a few milliseconds.
openaire +2 more sources
Applied Optics, 1973
When the absolute value X = ?Xmicro(micro).dmicro of incident radiation cannot be obtained from the output V = ?Xmicro(micro) R(x)(micro) dmicroof a selective instrument, with nonuniform responsivity R(x)(micro) = V(micro)(micro)/X(micro)(micro), because the incident distribution X(micro),(micro) is not known, recourse is had to various normalization ...
openaire +2 more sources
When the absolute value X = ?Xmicro(micro).dmicro of incident radiation cannot be obtained from the output V = ?Xmicro(micro) R(x)(micro) dmicroof a selective instrument, with nonuniform responsivity R(x)(micro) = V(micro)(micro)/X(micro)(micro), because the incident distribution X(micro),(micro) is not known, recourse is had to various normalization ...
openaire +2 more sources
Ultraviolet radiometry with synchrotron radiation and cryogenic radiometry
Applied Optics, 1999The combination of a cryogenic radiometer and synchrotron radiation enables detector scale realization in spectral regions that are otherwise difficult to access. Cryogenic radiometry is the most accurate primary detector-based standard available to date, and synchrotron radiation gives a unique broadband and continuous spectrum that extends from x ray
P S, Shaw +8 more
openaire +2 more sources

