Results 101 to 110 of about 1,600,430 (391)

Designing Thermally Compatible Template‐Coating Pairs Toward Dimensionally Stable 3D Porous Carbons with Tunable Density

open access: yesAdvanced Functional Materials, EarlyView.
3D porous carbons with tunable density are crucial for energy storage, separations, and load‐bearing applications; however, their fabrication is often constrained by shrinkage during pyrolysis. This study optimizes and demonstrates the versatility of a template–coating pair strategy, producing materials that largely retain their shape and hierarchical ...
Adarsh Suresh   +7 more
wiley   +1 more source

Functional Outcome of Radius Ulna Fracture Treated With Nailing in Adults

open access: yesJournal of Orthopedic and Spine Trauma
Background: Intramedullary nailing (IMN) of radius and ulna has its own advantages and disadvantages. The chances of infection are significantly decreased, as it is usually a closed procedure and has less periosteal stripping.
Ishani Patel   +5 more
doaj   +1 more source

Scaling forces to asteroid surfaces: The role of cohesion

open access: yes, 2010
The scaling of physical forces to the extremely low ambient gravitational acceleration regimes found on the surfaces of small asteroids is performed. Resulting from this, it is found that van der Waals cohesive forces between regolith grains on asteroid ...
Hartzell, C. M.   +3 more
core   +1 more source

Reconfigurable Metamirrors Based on Compliant Mechanisms

open access: yesAdvanced Functional Materials, EarlyView.
Providing the basis for numerous practical applications, the reconfigurability of metadevices is of great importance. Through the integration of controlled mechanical deformation with chiral meta‐atoms, a compliant mechanism based metamirror is demonstrated for active control over the polarization of electromagnetic waves.
Galestan Mackertich‐Sengerdy   +3 more
wiley   +1 more source

Impact of Completion on Wellbore Skin Effect [PDF]

open access: yes, 2012
Imperial Users ...
Alshawaf, Mohammed, Alshawaf, Mohammed
core  

Reproducibilty of partial weight bearing [PDF]

open access: yes
Objectives: To find out whether partial weight bearing can be reproduced and retained. Design: In vivo experiment in normal subjects. Intervention: Training for partial weight bearing (25% of body weight) using bathroom scales.
Doyle, J   +4 more
core   +1 more source

Displaced distal radius fractures in children, cast alone vs additional K-wire fixation: a meta-analysis

open access: yesEuropean Journal of Trauma and Emergency Surgery, 2018
PurposeDisplaced distal radius fractures in children are common and often treated by reduction and cast immobilization. Redisplacement occurs frequently and may be prevented by additional treatment with K-wire fixation after initial reduction.
A. Sengab, P. Krijnen, I. Schipper
semanticscholar   +1 more source

Two‐Dimensional Materials as a Multiproperty Sensing Platform

open access: yesAdvanced Functional Materials, EarlyView.
Various sensing modalities enabled and/or enhanced by two‐dimensional (2D) materials are reviewed. The domains considered for sensing include: 1) optoelectronics, 2) quantum defects, 3) scanning probe microscopy, 4) nanomechanics, and 5) bio‐ and chemosensing.
Dipankar Jana   +11 more
wiley   +1 more source

Minimally Invasive Plate Osteosynthesis (MIPO) of Comminuted Radial Fractures Using a Locking Plate Contoured on a 3D-Printed Model of the Feline Antebrachium: A Cadaveric Study

open access: yesAnimals
(1) Background: Due to the unique structural and functional characteristics of the forelimb in cats, fractures of the radius and ulna are best repaired using internal fixation and stabilization in accordance with AO principles.
Piotr Trębacz   +5 more
doaj   +1 more source

Home - About - Disclaimer - Privacy