Results 171 to 180 of about 309,383 (270)

Low SLC8A1 in Colorectal Cancer Dictates Radiotherapy Resistance Through Calcium‐Dependent ANXA2+sEVs Driving M2 Polarization of TAMs

open access: yesAdvanced Science, Volume 13, Issue 63, 12 November 2026.
SLC8A1 deficiency in colorectal cancer cells increases intracellular calcium signaling, promoting the secretion of ANXA2‐enriched small extracellular vesicles. These vesicles reprogram tumor‐associated macrophages towards an M2 phenotype, which in turn fosters a tumor microenvironment conducive to radioresistance and is associated with poor patient ...
Yimin Fang   +18 more
wiley   +1 more source

Oxygen-Tolerant RAFT Polymerization Initiated by Living Bacteria. [PDF]

open access: yesACS Macro Lett, 2022
Bennett MR   +9 more
europepmc   +1 more source

Functional Polymer‐Engineered Magnetic Nanoparticles as Dual‐Modal Theragnostic Probes for Early Alzheimer's Disease Detection and Therapy

open access: yesAdvanced NanoBiomed Research, Volume 6, Issue 11, November 2026.
The nanoparticle consists of a 3 nm iron oxide core functionalized with an amphiphilic polymer coating containing Aβ‐targeting DSA moieties and biocompatible PEG chains. This design supports measurable transport in a BBB‐related model and specific interaction with Aβ species, while providing MRI contrast enhancement for diagnosis and therapeutic ...
Ao Shen   +8 more
wiley   +1 more source

pH‐Responsive Ultrasmall Iron Oxide Nanoassemblies for Activatable T2/T1 Magnetic Resonance Imaging

open access: yesAdvanced NanoBiomed Research, Volume 6, Issue 11, November 2026.
This research reports a pH‐responsive ultrasmall iron oxide nanoparticle (USIONs)/polymer nanoassemblies for activatable magnetic resonance imaging. Amphiphilic diphosphonic acid block copolymers compactly encapsulate USIONs to generate T2‐weighted contrast at physiological pH, while acidic conditions trigger disassembly, activating T1‐weighted ...
Xumin Huang   +11 more
wiley   +1 more source

Upconversion Lateral Flow Test for A1 Beta‐Casein Protein in Milk and Infant Formulas

open access: yesAnalysis &Sensing, Volume 6, Issue 6, November 2026.
A1 and A2 β‐casein have similar structures but distinct health effects. We developed a rapid UCNP‐based lateral flow assay for sensitive A1 β‐casein detection. The assay provides quantitative detection from 0.001 to 10 ng/mL, with a 61 pg/mL detection limit and 10 min analysis time.
Ziwei Wu   +6 more
wiley   +1 more source

Home - About - Disclaimer - Privacy