Results 141 to 150 of about 633 (174)
Some of the next articles are maybe not open access.
RapidPlan Development of VMAT Plans for Cervical Cancer Patients in Low- and Middle-Income Countries
Medical Dosimetry, 2020Cervical cancer has a high incidence and mortality rate in low- and middle-income countries (LMICs) largely due to limited resources and insufficient staffing. Knowledge-based planning (KBP) could alleviate understaffing issues by streamlining the radiotherapy treatment planning process.
Rachel Hunter +2 more
exaly +3 more sources
Physica Medica, 2017
This study evaluated whether RapidPlan based plans (RP plans) created by a single optimization, are usable in volumetric modulated arc therapy (VMAT) for patients with prostate cancer.We used 51 previously administered VMAT plans to train a RP model. Thirty RP plans were created by a single optimization without planner intervention during optimization.
Hajime Monzen +2 more
exaly +3 more sources
This study evaluated whether RapidPlan based plans (RP plans) created by a single optimization, are usable in volumetric modulated arc therapy (VMAT) for patients with prostate cancer.We used 51 previously administered VMAT plans to train a RP model. Thirty RP plans were created by a single optimization without planner intervention during optimization.
Hajime Monzen +2 more
exaly +3 more sources
Medical Dosimetry, 2019
The aim of this study is to determine if RapidPlan (RP) can be used as a prediction method to determine which left-sided supine breast cancer patients would benefit from the deep inspiration breath-hold (DIBH) technique. An RP model database was created with 72 clinically approved 3D conformal radiation therapy (3D-CRT) treatment plans.
Nishele Lenards +2 more
exaly +3 more sources
The aim of this study is to determine if RapidPlan (RP) can be used as a prediction method to determine which left-sided supine breast cancer patients would benefit from the deep inspiration breath-hold (DIBH) technique. An RP model database was created with 72 clinically approved 3D conformal radiation therapy (3D-CRT) treatment plans.
Nishele Lenards +2 more
exaly +3 more sources
Efficiently train and validate a RapidPlan model through
Purpose The aim of this study was to propose and validate an intuitive method for training and to validate knowledge‐based planning ( KBP ) systems based on a patient‐specific plan quality scoring.
Marco, Fusella +5 more
openaire +2 more sources
RapidPlan models for prostate radiotherapy treatment planning with 10-MV photon beams
Journal of Radiotherapy in Practice, 2022Abstract Introduction: The RapidPlan is a radiotherapy planning tool that uses a dataset of approved plans to predict the dose distribution and automatically generates the dose–volume constraints for optimisation of the new plan. This study compares three strategies of model building for the treatment of prostate cancer with the 10-MV ...
Francesco Pupillo +4 more
openaire +1 more source
Parotids in RapidPlan Oropharynx Models: To Split or not to Split
2017Purpose Methods and materials Results Conclusion Personal information ...
openaire +1 more source
RapidPlan Implementation at RNSH and Our Experience to Date
2018Purpose: With increasing complex radiotherapy, it can be a challenge to consistently produce high quality radiation plans which accurately deliver dose to the target while sparing organs at risk (OAR), especially for inexperienced planners.
openaire +1 more source
A phantom geometry approach to develop a RapidPlan knowledge-based planning model
Medical DosimetryKnowledge-based radiation therapy (KBRT) models, including RapidPlan (RP), significantly improve treatment planning by enhancing both consistency and plan quality. This study focuses on the development and validation of an RP model utilizing phantom geometries that simulate prostate patient anatomies for optimized dosimetry. A library of 240 volumetric
Himank Kalra, Raj Pal Singh, Anuj Kumar
openaire +2 more sources
RAPIDPLAN MODEL TRAINING AND VALIDATION FOR BREAST IRRADIATION
Physica Medica, 2023V. Rosso +17 more
openaire +1 more source
Evaluation of feasibility DVH-guided re-optimization for RapidPlan-generated prostate VMAT plans
Medical DosimetryFeasibility dose-volume histogram (FDVH) can provide patient-specific information on the anatomically achievable dose range for organs at risk (OARs) and may complement knowledge-based planning using RapidPlan. This study evaluated whether FDVH-guided re-optimization can improve RapidPlan-generated prostate volumetric-modulated arc therapy (VMAT) plans.
Suzuka Hijiyama +9 more
openaire +2 more sources

