Results 1 to 10 of about 88,058 (210)

Novel Characterization of Si- and SiC-Based PWM Inverter Bearing Currents Using Probability Density Functions

open access: yesEnergies, 2022
The high frequency PWM voltage pulses from a two-level six-switch inverter produce a common-mode voltage in an electric machine’s windings, a fraction of which appears on the machine shaft due to electrostatic (capacitive) coupling.
Ryan Collin   +2 more
doaj   +1 more source

Study of Radiation-Chemical Structuring of Compositions Based on Epoxy Oligomers

open access: yesEast European Journal of Physics, 2020
The processes of radiation-chemical structuring of modified epoxy acrylic compositions were studied depending on the nature of epoxy oligomers and modifiers.
Lidiya F. Podhornaya   +2 more
doaj   +1 more source

Comparison of the Interrupting Capability of Gas Circuit Breaker According to SF6, g3, and CO2/O2 Mixture

open access: yesEnergies, 2020
In the study, an interrupting performance test on the 145 kV gas circuit breaker is performed according to three different gases: SF6, g3 (5% NovecTM4710 with 95% CO2), and CO2(70%)/O2(30%) gases. Thanks to research advancements, it is confirmed that CO2
Woo-Young Lee   +6 more
doaj   +1 more source

A Dual Enhancement Switching Technology for Vacuum Circuit Breakers in Various AC-Based Operational Environments

open access: yesIEEE Access
Vacuum circuit breakers (VCBs) have gained the attention of the medium voltage community for their involvement in various applications. However, the problem of arc-reignition is still under investigation with R-C snubber circuits considered as the most ...
Tamer Eliyan   +3 more
doaj   +1 more source

Combined Effect of the Parameters of Vacuum Interrupter and L-C Circuit Upon Arc Re-Ignition in HVDC Circuit Breakers

open access: yesIEEE Access
The new horizons for HVDC systems and their applications has intensified the research in HVDC protection systems. The HVDC circuit breakers (CB) has been the center of the protection systems with vacuum interrupters (VIs) showcasing a great potential for
Tamer Eliyan   +3 more
doaj   +1 more source

Study on Flow and Heat Transfer Characteristics of Battery Thermal Management System with Supercritical CO2 for Energy Storage Stations

open access: yesEnergies
Energy storage stations (ESSs) need to be charged and discharged frequently, causing the battery thermal management system (BTMS) to face a great challenge as batteries generate a large amount of heat with a high discharge rate.
Ya Wang   +4 more
doaj   +1 more source

Study on the influence of mechanism dispersion on transient recovery voltage distribution of modular DC vacuum circuit breakers

open access: yesHigh Voltage
A simulation analysis and an experiment are carried out to investigate how the gap difference between the breaks of a direct current vacuum circuit breakers with multi‐breaks (MB‐DC VCB) caused by the mechanism dispersion of the breaker influences the ...
Chongyang Huang   +6 more
doaj   +1 more source