Results 1 to 10 of about 27,245 (281)
Active Power Dispatch Plan among Units in DFIG Based Wind Farm [PDF]
During normal operation, doubly-fed induction generator (DFIG) can generate certain range of reactive power according to the requirements of the power grid.
Lefeng Zhang, Zengping Wang
doaj +1 more source
The appropriate control and management of reactive power is of great relevance in the electrical reliability, stability, and security of power grids.
Mohamed H. Hassan +4 more
doaj +1 more source
This paper proposes a modification method focusing on the distance‐based reactive power dispatch method that is applied in wind farm structures. Due to the continuous expansion of grid requirements, the development of new approaches needs to be more ...
Seungmin Jung
doaj +1 more source
For the microgrids to operate securely, distributed generators must be able to interact with one another without experiencing any communication delays or noise.
Shruti Singh, David Wenzhong Gao
doaj +1 more source
The intermittent property and increased grid restrictions have become the most critical elements for increasing penetration levels of clean renewable energy sources (RESs).
Sayed M. Said +2 more
doaj +1 more source
Electric power dispatch issue mainly consists of two optimization tasks: active and reactive power dispatches, each of which is a non-linear multi-objective optimization problem with a series of constraints.
Junwei Liu +5 more
doaj +1 more source
One of the most important Distribution System Operators (DSO) schemes addresses the Volt/Var control (VVC) problem. Developing a cost-based reactive power dispatch model for distribution systems, in which the reactive powers are appropriately priced, can
Abouzar Samimi, Ahad Kazemi
doaj +1 more source
Reactive Power Dispatch Method in Wind Farms to Improve the Lifetime of Power Converter Considering Wake Effect [PDF]
In Wind Farms (WF), the most popular and commonly implemented active power control method is the Maximum Power Point Tracking (MPPT). Due to the wake effect, the upstream Wind Turbine (WT) in WFs has more active power generation than the downstream WT at
Blaabjerg, Frede +4 more
core +2 more sources
In this paper, a flexible power dispatch strategy based on the elliptical trajectory is proposed to maximize the operating region for dynamic voltage restorer (DVR) during voltage sags.
Peng Li +5 more
doaj +1 more source
Optimal security-constrained power scheduling by Benders decomposition [PDF]
This paper presents a Benders decomposition approach to determine the optimal day-ahead power scheduling in a pool-organized power system, taking into account dispatch, network and security constraints.
Fernández, José L. +2 more
core +2 more sources

