Results 281 to 290 of about 2,274,708 (332)

Real Options with Unknown-Date Events [PDF]

open access: yes
Francisco Ruiz-Aliseda   +1 more
core  

Evaluation of the system accuracy of frameless stereotactic radiosurgery using a combination of cone beam CT, six degrees of freedom couch, and surface image‐guided systems

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study aims to evaluate the accuracy of the frameless linear accelerator‐based stereotactic radiosurgery (FSRS) system incorporating cone‐beam CT (CBCT), six degrees of freedom (6‐DoF) couch, room laser, and surface image‐guided (SG) systems.
Hao‐Wen Cheng   +4 more
wiley   +1 more source

Comprehensive clinical evaluation of novel 4DCT‐based lung function imaging methods

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Methods have been developed that apply image processing to 4DCTs to generate 4DCT‐ventilation/perfusion lung imaging. Traditional methods for 4DCT‐ventilation rely on Hounsfield‐Unit (HU) density‐change methods and suffer from poor numerical robustness while not providing 4DCT‐perfusion data.
Ehsan Golkar   +6 more
wiley   +1 more source

An extension to the OVH concept for knowledge‐based dose volume histogram prediction in lung tumor volumetric‐modulated arc therapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Volumetric‐modulated arc therapy (VMAT) treatment planning allows a compromise between a sufficient coverage of the planning target volume (PTV) and a simultaneous sparing of organs‐at‐risk (OARs). Particularly in the case of lung tumors, deciding whether it is possible or worth spending more time on further improvements of a treatment
Johann Brand   +4 more
wiley   +1 more source

Design and validation of a novel dosimetry phantom for motion management audits

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background We present a novel phantom design for conducting end‐to‐end dosimetry audits for respiratory motion management of two anatomical treatment sites. The design enables radiochromic film measurements of the dose administered to the target throughout the respiratory cycle (motion‐included) and the dose delivered to the time‐averaged ...
Alex Burton   +5 more
wiley   +1 more source

Perspective on the use of optics in bladder cancer detection and diagnosis. [PDF]

open access: yesJ Biomed Opt
Remmelink MJ   +5 more
europepmc   +1 more source

Novel CT radiomics models for the postoperative prediction of early recurrence of resectable pancreatic adenocarcinoma: A single‐center retrospective study in China

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose To assess the predictive capability of CT radiomics features for early recurrence (ER) of pancreatic ductal adenocarcinoma (PDAC). Methods Postoperative PDAC patients were retrospectively selected, all of whom had undergone preoperative CT imaging and surgery. Both patients with resectable or borderline‐resectable pancreatic cancer met
Xinze Du   +7 more
wiley   +1 more source

Chronic Hand Eczema, Real World, and Patient Centricity: A Narrative Review. [PDF]

open access: yesActa Derm Venereol
Molin S   +3 more
europepmc   +1 more source

Home - About - Disclaimer - Privacy