Results 11 to 20 of about 1,726 (153)

Methods and restrictions to increase the volume of resonant rectangular-section haloscopes for detecting dark matter axions [PDF]

open access: yesJournal of High Energy Physics, 2023
Haloscopes are resonant cavities that serve as detectors of dark matter axions when they are immersed in a strong static magnetic field. In order to increase the volume and improve space compatibility with dipole or solenoid magnets for axion searches ...
J. M. García-Barceló   +7 more
doaj   +6 more sources

Fabrication and Characterization of a Flexible Fluxgate Sensor with Pad-Printed Solenoid Coils [PDF]

open access: yesSensors, 2020
This paper presents the fabrication and characterization of a flexible, flat, miniaturized fluxgate sensor with a thin amorphous rectangular magnetic core fabricated by the pad/printing technique.
Spyridon Schoinas   +3 more
doaj   +2 more sources

D0 Solenoid Upgrade Project: Rectangular Liquid Helium Tube, Miscellaneous Information [PDF]

open access: yes, 1993
This engineering note contains miscellaneous information about the rectangular liquid helium supply tube for the D-Zero solenoid. The information is fairly superficial, but could be used as a starting point for a future engineer who is going to specify and puchase the tubing.
Rucinski, R.
openaire   +4 more sources

Micro Fluxgate Sensor using Solenoid Coils Fabricated by MEMS Technology [PDF]

open access: yesMeasurement Science Review, 2012
In this paper, we present a micro fluxgate sensor with solenoid coils. Micro-solenoid coils were used in this fluxgate sensor as excitation and sensing elements. Two identical excitation coils in inverse series were wound around the opposite sides of the
Lei Jian, Lei Chong, Zhou Yong
doaj   +2 more sources

Zero-Pole Optimization of a Novel High-Quality-Factor Planar Helical Resonator [PDF]

open access: yesMagnetism, 2023
A novel micro-solenoid resonator has been designed, simulated, and measured. The solenoid core consisted of a DuroidTM circuit board with a relative permittivity of 2.2.
Reza Kamali-Sarvestani, John D. Williams
doaj   +2 more sources

A Strong Misalignment Tolerance Wireless Power Transfer System for AUVs with Hybrid Magnetic Coupler [PDF]

open access: yesJournal of Marine Science and Engineering
Wireless power transfer systems require not only strong coupling capabilities but also stable output under various misalignment conditions. This paper proposes a hybrid magnetic coupler for autonomous underwater vehicles (AUVs), featuring two identical ...
Haibing Wen   +9 more
doaj   +2 more sources

Self-Inductance of the Circular Coils of the Rectangular Cross-Section with the Radial and Azimuthal Current Densities [PDF]

open access: yesPhysics, 2020
In this paper, we give new formulas for calculating the self-inductance for circular coils of the rectangular cross-sections with the radial and the azimuthal current densities.
Slobodan Babic, Cevdet Akyel
doaj   +3 more sources

Concave Contact Geometry for Enhanced Sealing and Structural Integrity in Ultra-High Pressure Hydrogen Solenoid Valves [PDF]

open access: yesApplied Sciences
Ultra-high-pressure hydrogen solenoid valves face a fundamental design challenge of operating across a wide pressure range from 2 MPa to 87.5 MPa. To address the conflicting requirements of effective sealing at low pressures and structural integrity at ...
Jaeseong Choi, Hwayoung Kim
doaj   +2 more sources

New symmetric and lattice shaped high-temperature superconducting coil cross sections [PDF]

open access: yesResults in Physics, 2016
To improve the performances of high-temperature superconducting (HTS) coils, it is necessary to store more energy within a shorter HTS tape length and to reduce leakage magnetic fields.
Naoya Uchiyama, Shinichi Ishiguri
doaj   +2 more sources

Effect of Magnetic Field on Adhesion of Muscle Cells to Culture Plate [PDF]

open access: yesJournal of Systemics, Cybernetics and Informatics, 2013
The effect of a magnetic field on adhesion of cultured muscle cells to the culture plate has been studied in vitro. An experimental system was manufactured to apply a magnetic field to muscle cell culture.
Shigehiro Hashimoto, Keiji Tachibana
doaj   +2 more sources

Home - About - Disclaimer - Privacy