Results 191 to 200 of about 466,978 (244)

Hydrogen Analyses of FSW Cu‐OFP Tested Under Creep Conditions in Sulphide Containing Environment

open access: yesMaterials and Corrosion, EarlyView.
Friction stir welded Cu‐OFP exhibits elevated creep rates in sulphide‐containing aqueous environments, with creep increasing as sulphide concentration rises. Hydrogen measurements indicate that sulphide exposure does not increase hydrogen content. ABSTRACT Friction stir welded oxygen‐free phosphorus‐doped copper (FSW Cu‐OFP) is a candidate material for
Patrik Sahiluoma   +3 more
wiley   +1 more source

Genomic variation in <i>Pseudomonas aeruginosa</i> clinical respiratory isolates with <i>de</i> <i>novo</i> resistance to a bacteriophage cocktail. [PDF]

open access: yesMicrobiol Spectr
Fong SA   +8 more
europepmc   +1 more source

Understanding Algorithm Discounting in Artificial Intelligence Recommendations: Matching Anthropomorphic Agents to Consumer Goals

open access: yesPsychology &Marketing, EarlyView.
ABSTRACT Despite the proliferation of artificial intelligence (AI) in marketing, consumers often exhibit algorithm discounting—a tendency to evaluate AI‐generated recommendations less favorably than those from humans. Focusing on consumption goals, this study investigates how anthropomorphic AI agents (virtual assistants vs.
Jiayue Huang   +4 more
wiley   +1 more source

Towards quality indicators in palliative care education: An umbrella review. [PDF]

open access: yesPalliat Care Soc Pract
Pedrosa AJ   +13 more
europepmc   +1 more source

Improved Accuracy of Multidimensional Spatially‐Selective Saturation RF Pulses for Short‐Repetition‐Time Steady‐State Imaging

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To introduce and evaluate a novel RF pulse design algorithm for multi‐dimensional spatially tailored excitation that is optimized for spoiled steady‐state gradient echo MRI sequences. Methods Existing multi‐dimensional RF pulse design algorithms optimize RF and gradient waveforms using a loss function based on a single RF pulse ...
Yongli He   +2 more
wiley   +1 more source

Whole‐Brain Diffusion MRI at 7T With Universal Multiband GRAPE pTx Pulses

open access: yesMagnetic Resonance in Medicine, EarlyView.
Purpose To improve signal strength and homogeneity of whole‐brain diffusion‐weighted imaging (DWI) at 7T. Methods Universal multiband excitation and refocusing pulses were optimized with the gradient ascent pulse engineering (GRAPE) algorithm across a database of B1+$$ {B}_1^{+} $$ and B0$$ {B}_0 $$ maps obtained from 20 subjects.
Marten Laufenberg   +5 more
wiley   +1 more source

A Modular Hybrid Framework for CEST MRI Development and Clinical Translation Using pTx‐Pulseq Preparation With Open‐ and Closed‐Source Readouts and ONNX Mapping

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose Chemical exchange saturation transfer (CEST) MRI offers unique metabolic insights for imaging of cancer, stroke, or neurodegeneration. However, the rapid expansion of CEST preparation schemes and evaluation techniques creates a bottleneck; novel methods often remain complex prototypes requiring offline processing, preventing clinical ...
Martin Freudensprung   +9 more
wiley   +1 more source

Simultaneous T1 and T2 Mapping in the Brain With QuantoRAGE: An MP2RAGE Variant Using T2‐Prepared Inversion

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To develop and validate a repeatable and reproducible approach, QuantoRAGE, for simultaneous whole‐brain T1 and T2 mapping using adiabatic magnetization preparation. Methods QuantoRAGE is a 3D FLASH‐based sequence using an adiabatic T2‐prepared inversion followed by two readout blocks.
Natalia Pato Montemayor   +21 more
wiley   +1 more source

Home - About - Disclaimer - Privacy