Results 101 to 110 of about 4,905,172 (289)
Thick film screen printed environmental and chemical sensor array reference electrodes suitable for subterranean and subaqueous deployments [PDF]
Purpose - Thick film environmental and chemical sensor arrays designed for deployment in both subterranean and submerged aqueous applications are reported.Design/methodology/approach - Various choices of materials for reference electrodes employed in ...
Atkinson, John +11 more
core +1 more source
Irreversibility of Ag|AgCl Reference Electrodes
An Ag|AgCl redox couple has been thought to work as a reversible reference electrode, although metal dissolution often occurs irreversibly. This report examines the kinetics by means of ac-impedance of AgCl films at the Ag electrode.
Koichi Jeremiah Aoki, Jingyuan Chen
doaj +1 more source
ABSTRACT Electronic waste has emerged as a major environmental challenge, driven by the massive consumption and a limited lifetime of modern electronic devices, stimulating the development of sustainable electronics. Here, an all‐biomaterial gelatin‐choline‐citric acid ([Ch][CA]) ionogel is developed as an active binder to realize self‐sintered ...
Lin Guo +10 more
wiley +1 more source
Citation: 'reference electrode' in the IUPAC Compendium of Chemical Terminology, 3rd ed.; International Union of Pure and Applied Chemistry; 2006. Online version 3.0.1, 2019. 10.1351/goldbook.R05229 • License: The IUPAC Gold Book is licensed under Creative Commons Attribution-ShareAlike CC BY-SA 4.0 International for individual terms.
openaire +1 more source
A soft, dual‐channel hydrogel patch enables simultaneous detection of wound temperature and strain by integrating ion‐diffusion‐mediated thermoelectric and resistive sensing. The conformal design maintains stable performance during motion, capturing subtle inflammatory and mechanical changes for continuous wound monitoring.
Yu Fang +7 more
wiley +1 more source
The nature of the solid electrolyte and the low electrode-electrode gap in polymer electrolyte fuel cells (PEFCs) makes it difficult to introduce a reference electrode into the fuel cell in order to separate anodic and cathodic overpotential ...
Scherer, G.G. (author) +3 more
core +1 more source
Investigating Na‐ion battery (SIB) materials is complicated by the absence of a well‐performing (reference) electrode material since sodium metal cannot be considered as a quasi‐reference electrode.
Dr. Fanglin Wu +5 more
doaj +1 more source
A STUDY ON pH ANALYZER USING ARTIFICIAL INTELLIGENCE IN WATER MANAGEMENT OF THERMAL POWER GENERATION PLANT [PDF]
pH is a very important factor that critically affects the efficiency of desulfurization facilities as well as in the generation of boiler tube scales in power plants as an indicator of hydrogen ion concentration of the aqueous solution.
Juhyeong KIL
doaj
Fully additive vertical organic electrochemical transistors (vOECTs) with channel‐length of 226 nm on a 50 µm compostable substrate achieve >106 current modulation and ∼36 mS transconductance. Ion‐selective integration enables 1.1 mA dec−1 sensitivity and 36 µm detection limit, highlighting a scalable platform for sustainable electronics and ...
Giulia Frusconi +3 more
wiley +1 more source
A reference electrode for use in supercritical difluoromethane
We describe the assembly and characterisation of a reference electrode for use in supercritical difluoromethane (R32). The reference electrode is constructed from a europium doped lanthanum fluoride crystal contacted by silver loaded epoxy and encased in
Cummings, Charles +7 more
core +1 more source

