Results 131 to 140 of about 4,628,362 (360)

Nano‐Patterned CuO Nanowire Nanogap Hydrogen Gas Sensor with Voids

open access: yesAdvanced Functional Materials, Volume 35, Issue 12, March 18, 2025.
Sub‐5‐ppb hydrogen (H2) detection and sub‐10‐s response and recovery times are achieved based on nano‐patterned polycrystalline CuO nanowires nanogap gas sensors with voids using electron‐beam lithography and unique annealing processes. Pre‐H2 annealing, void‐generating oxidation, and downscaled nanogap electrodes are key to improving the sensing ...
Muqing Zhao   +4 more
wiley   +1 more source

Device for quickly sensing the amount of O2 in a combustion product gas [PDF]

open access: yes, 1990
A sensing device comprising an O2 sensor, a pump, a compressor, and a heater is provided to quickly sense the amount of O2 in a combustion product gas.
Davis, William T.   +2 more
core   +1 more source

Errors in the reference electrode measurements in real lithium-ion batteries

open access: yes, 2021
Yalun Li   +8 more
semanticscholar   +1 more source

Magnetic Field‐Assisted Conductive Nerve Guidance Conduit Enabling Peripheral Nerve Regeneration with Wireless Electrical Stimulation

open access: yesAdvanced Functional Materials, EarlyView.
This study introduces a conductive nerve guidance conduit integrated with wireless electrical stimulation through alternating magnetic fields, which induces currents and creates a supportive microenvironment for nerve regeneration. In vivo studies show that this approach significantly enhanced myelin restoration, gastrocnemius muscle regeneration ...
Shiheng Liu   +7 more
wiley   +1 more source

A Portable Sensing System for Electronic Tongue Operations

open access: yesSensors, 2006
A portable, low cost sensing system is described which interfaces to an electronictongue sensor. The sensor used is a voltammetric sensor which monitors electrochemicalreactions that occur in solutions.
Kilian Murphy   +2 more
doaj   +1 more source

Electrochemical detection device [PDF]

open access: yes, 1979
A standard pH reference electrode and a platinum cathodic electrode are positioned in a container with suitable nutrient medium for microbial growth plus the sample to be tested.
Wilkins, J. R., Young, R. N.
core   +1 more source

Electrochemical Characterization of a Solid Embeddable Ag/AgCl Reference Electrode for Corrosion Monitoring in Reinforced Concrete

open access: yes, 2014
In this study, a new solid embeddable Ag/AgCl reference electrode (RE) was electrochemically investigated for corrosion monitoring in reinforced concrete. The electrode was fabricated by applying the cement mortar as the bottom layer, and the polymer gel
M. Jin   +7 more
semanticscholar   +1 more source

Fibrous Pb(II)‐Based Coordination Polymer Operable as a Photocatalyst and Electrocatalyst for High‐Rate, Selective CO2‐to‐Formate Conversion

open access: yesAdvanced Functional Materials, EarlyView.
A coordination polymer [Pb(tadt)]n prepared by a microwave‐assisted solvothermal method selectively reduces CO2 into formate under visible light with a high apparent quantum yield of ≈25% at 400 nm. It can function as a pre‐catalyst, along with conductive Ketjen Black, to form an active PbCO3/Pb3(CO3)2(OH)2 mixture that exhibits a high Faradaic ...
Chomponoot Suppaso   +8 more
wiley   +1 more source

Home - About - Disclaimer - Privacy