Results 321 to 330 of about 4,628,362 (360)
Some of the next articles are maybe not open access.

Disposable reference electrode

The Analyst, 1998
A disposable reference electrode was developed which can be used for environmental and medical analysis. It is an Ag/AgCl electrode with an integrated junction, prepared using inexpensive materials such as glass-fibre filter medium and heat-sealing film with screen printing and encapsulating by lamination.
openaire   +2 more sources

Fluoride-selective electrode with internal redox reference electrode

Mikrochimica Acta, 1995
The potential response of a symmetrical configuration in which the LaF3-membrance is placed between two solutions is discussed. The electrode body provides contact with the inner surface of the fluoride membrane, with a solution containing Fe(CN)63- - Fe(CN)64- redox couple and a Pt wire as internal reference electrode.
Njegomir Radić, Marija Bralić
openaire   +3 more sources

Alternative Reference Electrode Placements

American Journal of Electroneurodiagnostic Technology, 2007
The epileptologists asked the technologists in our laboratories to investigate the use of alternative references. The investigation included evaluation of each reference as well as the amount of time placing the additional references added to the procedure.
openaire   +3 more sources

An instantly usable paper-based screen-printed solid-state KCl/Ag/AgCl reference electrode with long-term stability.

In Analysis, 2015
An instantly usable screen-printed paper-based Ag/AgCl electrode was fabricated for use as a cost-effective disposable reference electrode. The reference electrode showed potential stability for approximately 75 h.
Isao Shitanda   +3 more
semanticscholar   +1 more source

Micro-reference Electrodes

2013
Rapid and accurate determination of ions in solutions is an increasing demand in medicine, research, routine work in laboratories as well as in process control. The development of portable chemical analysers is dependent on the ability to miniaturise the sensors.
openaire   +2 more sources

Copper sulfate reference electrode

Journal of Electroanalytical Chemistry, 2011
Abstract The goal of this experimental study was to accurately determine the potential of the copper sulfate electrode (CSE) for use in quantitative electrochemical analysis. The potential of the CSE at 25 °C was found to be 317 mV versus that of the normal hydrogen electrode (NHE), with a slope of 0.17 mV/°C over the range from 5 °C to 45 °C.
Donald R. Sadoway   +2 more
openaire   +2 more sources

Pseudo-reference Electrodes

2013
Both the terms of pseudo-reference (literally “false” reference) electrode and quasi-reference (“almost” or “essentially”) electrode are used in the literature, often synonymously or interchangeably. The essential difference between a true reference electrode (as defined in Chap.
openaire   +2 more sources

Rehydrating dry reference electrodes

Journal of Chemical Education, 1993
For solutions containing protein, this apparatus avoids the problems caused when using silver chloride solutions that plug up ion junctions.
openaire   +2 more sources

Instrument-free control of the standard potential of potentiometric solid-contact ion-selective electrodes by short-circuiting with a conventional reference electrode.

Analytical Chemistry, 2014
A simple, instrument-free method to control the standard potential (E°) of potentiometric solid-contact ion-selective electrodes (SC-ISE) is described. In this method, the electrode potential of a SC-ISE is reset by short-circuiting the electrode with a ...
Ulriika Vanamo, J. Bobacka
semanticscholar   +1 more source

Reference electrodes based on conducting polymers

Fresenius' Journal of Analytical Chemistry, 2000
Several attempts to produce conducting polymer based all-solid-state reference electrodes are presented. Open circuit potential of conducting polymers is redox sensitive and Donan equilibrium dependent. Therefore, more sophisticated constructions are necessary.
K. Jüttner   +2 more
openaire   +3 more sources