Results 81 to 90 of about 883 (240)
Recent Advances in Ferrite‐Based Materials for Biomedical Applications: A Comprehensive Review
Ferrite nanoplatforms are presented as tunable biomedical materials in which synthesis control, cation engineering, defect/morphology regulation, and surface functionalization govern structure–property–bioactivity relationships. These design strategies enable multifunctional applications including MRI contrast, magnetic hyperthermia, targeted drug ...
Pramod D. Mhase +6 more
wiley +1 more source
Electrically Coded Retinomorphic Spectrophotodetector
Self‐powered retinomorphic pyro‐photodetector is demonstrated that avoids machine‐learning post‐processing and covers 365–940 nm. Electrostatic balancing of built‐in potential produces an electrical wavelength code, delivering <3 nm wavelength decoding accuracy with ∼46 µs response.
Mohit Kumar, Hyunmin Dang, Hyungtak Seo
wiley +1 more source
Intrinsically Stretchable Piezoelectric Nanocomposites for Artificial Ultrasonic Sensory Synapse
Applying ultrasonic stimulations to a soft‐stretchable underwater piezoelectric sensor based on the soft‐stretchable nanocomposite from the thermal cross‐linking between the ─C─F group of P(VDF‐TrFE) and the ─NH2 group of (PEG‐diamine) with incorporating amine‐terminated BTO@APTES nanofillers on the soft PDMS substrates generated high piezoelectric ...
Trung Dieu Do +11 more
wiley +1 more source
Ionic conjugated polyelectrolyte electron‐blocking layers enable photomultiplication organic photodetectors with dark current robustness up to −10 V and external quantum efficiencies exceeding 3000%. Fowler–Nordheim tunneling, interfacial dipole, trap density of states, and noise analyses reveal how ionic conjugated polyelectrolytes suppress electron ...
Yelim Kang +12 more
wiley +1 more source
Maskless Fabrication of PLA‐Based Neural Arrays for CNS Recording and Stimulation
Biodegradable neural interfaces enable bidirectional communication with the CNS. Through electrochemical characterization, ageing tests with impedance monitoring, and in vivo validation, we assess the performance of PLA‐based epicortical and spinal implants.
Anna De Salvo +14 more
wiley +1 more source
Fabrication of TiN/TiO2 Nanotube‐Based Heterostructure for Hydrogen Sensing Applications
A hydrogen sensor based on titanium dioxide nanotubes coated with titanium nitride has been developed. The coating process causes a mixed titanium oxynitride layer to form, which improves the sensor performance. Sensor response R depends on the TiN thickness and is not degraded after 7 days in air.
Esme Isik +4 more
wiley +1 more source
Reflections in semiconductor optical amplifiers (SOAs), especially in heterogeneously integrated silicon photonics platforms where isolators are absent, can severely degrade performance through nonlinear gain dynamics and excess noise. Even weak reflections can induce backward-propagating fields that can coherently interfere with the forward ...
Swarnav Banik, Ashish Bhardwaj
openaire +2 more sources
Flexible Wide Bandgap Electrode System for In situ Cell Sensing and Irreversible Electroporation
The paper reports the design and wafer‐level microfabrication of a long‐lived, flexible 3C‐SiC electrode capable of sensitive and in situ cell sensing, as well as electroporation ablation. The work demonstrates a biocompatible and durable electrode platform that can perform reliable electrical interfacing with biological tissues over extended periods ...
Minh Anh Huynh +3 more
wiley +1 more source
Multimodal Haptic Perception Through Synergistic Nanocomposite Sensor Arrays
Multi‐modal fingertip haptics are advanced through a bioinspired &vertical‐via' electronic skin architecture. A confined PDMS/MWCNT/NiNP nanocomposite, sitting at the percolation threshold, enables tactile, thermal, and magnetic sensing. A unique via‐density gradient and dedicated &Un‐Touch' reference nodes provide robust spatial resolution and signal ...
Amos Bardea, Fernando Patolsky
wiley +1 more source
A flexible piezoresistive pressure sensor with gradient toroidal CNT/PDMS microstructures is reported. The hierarchical geometry enables sequential electrode contact, achieving a sensitivity of 256.20 kPa−1 and linear response (R2 = 0.99) over 0–1000 kPa.
Rongmei Wang +8 more
wiley +1 more source

