Results 101 to 110 of about 11,931 (201)

Multi‐Parametric Phase‐Cycled Balanced Steady‐State Free Precession Brain Tissue Characterization in Relapsing‐Remitting Multiple Sclerosis

open access: yesJournal of Magnetic Resonance Imaging, EarlyView.
ABSTRACT Background Time‐efficient phase‐cycled balanced steady‐state free precession (pc‐bSSFP) imaging is a novel microstructure‐ and myelin‐sensitive approach for multi‐parametric brain tissue characterization not yet evaluated in demyelinating diseases such as multiple sclerosis (MS).
Florian Birk   +9 more
wiley   +1 more source

Preoperative expectations and 2‐year outcomes after primary anterior cruciate ligament reconstruction

open access: yesKnee Surgery, Sports Traumatology, Arthroscopy, EarlyView.
Abstract Purpose A growing emphasis on patient‐centered care, paired with a steady rise in anterior cruciate ligament reconstructions (ACLRs), has led to greater interest in identifying predictors of patient‐reported outcomes (PROs) after ACLR. Patient expectations are one factor previously identified as potentially impacting post‐operative PROs in ...
Prateek Swamykumar   +9 more
wiley   +1 more source

Dual‐Metasurface‐Integrated Fiber Array for Bidirectional Cylindrical‐Vector‐Beam Multiplexed Communication Using Off‐Axis Spatial Manipulation

open access: yesLaser &Photonics Reviews, EarlyView.
A dual‐layer metasurface is integrated on a fiber‐array facet to realize compact, plug‐and‐play free‐space optical links with cylindrical vector beam (CVB) space‐division multiplexing. An optimized off‐axis collimation layer steers multiple channels, while a Dammann vortex layer performs polarization–topology conversion for bidirectional CVB (de ...
Xipeng Lu   +6 more
wiley   +1 more source

Fungsi legislatif dalam kebijakan refocusing anggaran di Kabupaten Bandung Tahun 2020-2021 [PDF]

open access: yes
Masalah yang diakibatkan pandemi membuat pemerintah Indonesia mengeluarkan kebijakan penanganan Covid-19 terhadap belanja keuangan pemerintah, yakni Instruksi Presiden No. 4Tahun 2020 tentang Refocusing Anggaran.
Afani, Akhira   +2 more
core   +1 more source

Intensity Noise Dynamics in Terahertz Quantum Cascade Lasers

open access: yesLaser &Photonics Reviews, EarlyView.
Intensity‐noise dynamics in terahertz quantum cascade lasers are investigated across single‐mode, dense‐comb and harmonic‐comb regimes using graphene thermoelectric detectors. Harmonic combs show ∼10% lower relative intensity noise, while RIN scales as P0−γ$P_0^{ - \gamma }$ with γ≈1.2$\gamma \approx 1.2$, revealing a crossover from spontaneous ...
M. Alejandro Justo‐Guerrero   +5 more
wiley   +1 more source

Characterization and Repetition Rate Locking of a 1 GHz Erbium‐Doped ZBLAN Waveguide‐Chip Comb Laser

open access: yesLaser &Photonics Reviews, EarlyView.
A compact, erbium‐doped ZBLAN waveguide chip mode‐locked laser that self‐starts, delivers stable ultrashort pulses, and repetition rate locked to a 1 GHz radio‐frequency reference. The laser produces near transform‐limited 324 fs pulses and 12 nm bandwidth with low noise and long‐term stability, with potential applications in optical frequency ...
Wen Qi Zhang   +4 more
wiley   +1 more source

Navigating Guaiacyl and Syringyl Lignin Structural Complexity in Intact Plant Cell Walls Through 13C Chemical Shift Mapping by Two‐Dimensional Solid‐State NMR

open access: yesMagnetic Resonance in Chemistry, EarlyView.
We establish a two‐dimensional solid‐state NMR 13C chemical shift mapping framework that resolves diagnostic features and explicitly visualizes spectral overlap among guaiacyl and syringyl lignin substructures in intact plant cell walls. Application across Arabidopsis genotypes and developmental stages, hardwoods, and softwood reveals distinct lignin ...
Peng Xiao   +7 more
wiley   +1 more source

Two-sided residual refocusing for an acoustic lens-based photoacoustic imaging system

open access: yes, 2018
In photoacoustic (PA) cameras, an acoustic lens-based system can form a focused image of an object plane. A real-time C-scan PA image can be formed by simply time gating the transducer response. While most of the focusing action is performed by the lens,
Francis, Kalloor Joseph   +11 more
core   +1 more source

Optimal‐Control 19F PROJECT Improves the Reliability of CPMG‐Derived Relaxation Rates

open access: yesMagnetic Resonance in Chemistry, EarlyView.
PROJECT with seedless optimal control pulses for 19F‐based protein‐ligand interaction screenings allows for a lower error in R2 estimates than those obtained with CPMG for J‐coupled fluorine signals and is indistinguishable from CPMG when the coupling is negligible, at the price of a modest reduction in SNR.
Marco Schiavina   +2 more
wiley   +1 more source

Simultaneous T1 and T2 Mapping in the Brain With QuantoRAGE: An MP2RAGE Variant Using T2‐Prepared Inversion

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To develop and validate a repeatable and reproducible approach, QuantoRAGE, for simultaneous whole‐brain T1 and T2 mapping using adiabatic magnetization preparation. Methods QuantoRAGE is a 3D FLASH‐based sequence using an adiabatic T2‐prepared inversion followed by two readout blocks.
Natalia Pato Montemayor   +21 more
wiley   +1 more source

Home - About - Disclaimer - Privacy