Results 111 to 120 of about 22,412 (268)

Field Strength‐Dependent White Matter R1 and R2 Anisotropy of Phase‐Cycled Balanced Steady‐State Free Precession Relaxometry

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To investigate how the relaxation rates (R1, R2) and asymmetry indices (AI), derived from phase‐cycled balanced steady‐state free precession (pc‐bSSFP) data, depend on the orientation of white matter (WM) fiber tracts at different field strengths.
Florian Birk   +8 more
wiley   +1 more source

Magnetic Resonance imaging (MRI) in detection of _Bifidobacterium longum_ and _Clostridium novyi-NT_ labeled with superparamagnetic iron oxide (SPIO) nanoparticle [PDF]

open access: yes, 2009
*Purpose:* To investigate the MR imaging of _Bifidobacterium longum_ and _Clostridium novyi-NT_ labeling with superparamagnetic iron oxide (SPIO) nanoparticles. *Materials and methods:* Tubes containing _B. longum_-SPIO, Free-SPIO, _B.
Dan Li   +4 more
core   +1 more source

Analytic treatment of nuclear spin-lattice relaxation for diffusion in a cone model

open access: yes, 2011
We consider nuclear spin-lattice relaxation rate resulted from a diffusion equation for rotational wobbling in a cone. We show that the widespread point of view that there are no analytical expressions for correlation functions for wobbling in a cone ...
A.E. Sitnitsky   +57 more
core   +1 more source

Quantitative Comparison of Multi‐Echo Spin Echo and Multi‐Echo Gradient Echo Myelin Water Imaging in a Panel of Mbp Enhancer‐Edited Mouse Lines

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To evaluate the correspondence between myelin water fraction (MWF) estimates derived from multi‐echo spin echo (MESE) and multi‐echo gradient echo (MGRE) imaging in fixed mouse brain tissue, using a panel of myelin basic protein (Mbp) enhancer‐edited mouse lines exhibiting graded hypomyelination.
Vladimir Grouza   +11 more
wiley   +1 more source

Rapid Field-Cycling MRI using Fast Spin-Echo [PDF]

open access: yes, 2013
The author acknowledges funding from the EPSRC through the Centre for Doctoral Training in Integrated Magnetic Resonance.Non peer reviewedPublisher ...
Broche, Lionel   +2 more
core  

Assessment of Optimal T1/T2‐Weighted Combinations for Myelin Sensitivity: Effects of Echo Time and Exponents

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose The aim of this study is to improve the traditional T1‐weighted (T1w) over T2‐weighted (T2w) ratio as a proxy for myelin by investigating the optimal T2w TE and combination of exponent‐weighted T1w and T2w images (T1wx1/T2wx2$$ \mathrm{T}1{\mathrm{w}}^{x_1}/\mathrm{T}2{\mathrm{w}}^{x_2} $$).
Simone Monachino   +7 more
wiley   +1 more source

Simultaneous Volumetric T1 and T2 Mapping With Blood‐ and Fat‐Suppression in Abdominal Aortic Aneurysms

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To develop and validate a protocol for simultaneous volumetric T1 and T2 mapping with blood‐ and fat‐suppression, and apply it to patients with abdominal aortic aneurysms (AAA) to assess tissue characteristics. Methods A spoiled gradient echo (SPGR) variable flip angle (VFA) acquisition was modified with preparation modules to suppress
Wilhelm Stehling   +7 more
wiley   +1 more source

Editorial: Neurology and neuroimaging in exotic and non-domestic species

open access: yesFrontiers in Veterinary Science, 2022
Silke Hecht   +2 more
doaj   +1 more source

Ligand‐Driven Optimization of Iron Oxide Nanoprobes for In Vivo MRI Enhancement at Ultra‐High Field

open access: yesSmall, EarlyView.
Ligand‐tailored iron oxide nanoparticles reveal how surface chemistry controls T2 relaxivity and in vivo performance in ultra‐high‐field MRI. Systematic variation of hydrophilicity and charge across five coatings modulated r2 by up to 333 mm−1 s−1, with chemical properties, rather than shell thickness, dictating magnetic dephasing and enabling reliable
Pelayo García‐Acevedo   +6 more
wiley   +1 more source

Fitting Quality of NMR Relaxation Data to Differentiate Asphalt Binders

open access: yesPhyschem
Asphalt binder performance grades (PGs) are important metrics in designing pavements for effective transportation infrastructure. The PG system relies on the binder’s stiffness and is determined through energy- and time-intensive physical testing ...
Rebecca M. Herndon   +3 more
doaj   +1 more source

Home - About - Disclaimer - Privacy