Results 31 to 40 of about 2,561,471 (271)
In view of the fact that the actual operation information of sub-station relay protection device and the point table information of relay protection fault information system are still manually point-by-point proof reading.
Dongliang Nan +5 more
doaj +1 more source
Application of evolutionary algorithms for optimal directional overcurrent relay coordination [PDF]
Includes bibliographical references.Relay coordination is necessary to ensure that while protection relays operate as fast as possible, they are also able to isolate only the faulted parts of the system from the network, ensuring that a power system ...
Stenane, Ndabeni Moses
core +1 more source
Мета роботи. Визначення максимальних величин струмових та кутових похибок трансформаторів струму та характеру їх зміни в усталених та перехідних режимах енергосистеми, за яких можливий вихід величин похибок за межі діапазону нормованих значень, а також у
V. V. Nitsenko +2 more
doaj +1 more source
Achieving full diversity in multi-antenna two-way relay networks via symbol-based physical-layer network coding [PDF]
This paper considers physical-layer network coding (PNC) with M-ary phase-shift keying (MPSK) modulation in two-way relay channel (TWRC). A low complexity detection technique, termed symbol-based PNC (SPNC), is proposed for the relay.
Lv, Tiejun +4 more
core +1 more source
To reduce damage to electrical power equipment, protective equipment is needed that is designed as well as possible, so that the protection relay can isolate faults in parts of the distribution network as fast as possible.
Andy Frediansyah +2 more
doaj +1 more source
Analysis of operation of transformer differential protection under current transformer saturation: Software simulations and relay testing [PDF]
In the paper the analyses of the current transformer saturation influence to operation of differential protection are presented. Analyses are performed using a simulation tool and a relay model, as well as using the physical relay by injecting test ...
Sučević Nikola +2 more
doaj +1 more source
The disturbance of the high voltage transmission can be caused by a short circuit, overload, lightning surge, and other natural disturbances. That disturbance can lead to disruption of the distribution of electricity and damage to the electric power ...
Zulkarnaini Zulkarnaini, Rizki Muhammad
doaj +1 more source
Power grids often develop specialized startup plans for new equipment to standardize the commissioning process, which presents distinct challenges compared to other types of startup plans.
Wenbiao Tao +7 more
doaj +1 more source
The relay protection system’s composition in an intelligent substation.
The relay protection system’s composition in an intelligent substation.
Kai Yang (73590) +2 more
core +1 more source
Radio resource allocation in relay based OFDMA cellular networks [PDF]
PhDAdding relay stations (RS) between the base station (BS) and the mobile stations (MS) in a cellular system can extend network coverage, overcome multi-path fading and increase the capacity of the system.
Xiao, Lin