Results 101 to 110 of about 147,345 (296)

Experimental Study on the Combustion and Explosion Characteristics of Tributyl Phosphate and Kerosene Mixtures at Different Initial Pressures in High‐Temperature Environments

open access: yesEnergy Science &Engineering, EarlyView.
The explosion hazard of TBP and kerosene mixed vapor in the nuclear fuel reprocessing process is studied. The results enrich the explosion characteristics and explosion limits of TBP‐kerosene, and provide reference value and basis for the safety setting of the operation process and operating environment of nuclear fuel reprocessing plants ABSTRACT As ...
Pincong Wu   +6 more
wiley   +1 more source

A Review of Overcurrent Protection in Smart Grids Under Cyber‐Physical Threats With a Cyber‐Physical Evaluation Framework

open access: yesEnergy Science &Engineering, EarlyView.
By manipulating current and voltage measurements, an assailant can induce unwanted relay action while attempting to avoid detection. Detecting advanced cyber intrusions in power protection environments requires specialised data analysis and anomaly detection methods.
Feras Alasali   +6 more
wiley   +1 more source

PMU‐Based Wide Area Monitoring With Machine Learning to Prevent Blackouts in Bangladesh Power System

open access: yesEnergy Science &Engineering, EarlyView.
A Unified Real‐time Dynamic State Measurements (URTDSM) system with PMU and Phasor Data Concentrator (PDC) deployment plan has been proposed to avoid blackout in the Bangladeshi power system. Machine learning has been used to process data from PMU to identify abnormal events. ABSTRACT The electrical power system must be trustworthy and secure enough to
Imi Bintey Fariha Rahman   +5 more
wiley   +1 more source

Mitigating the impact of distributed generation on directional overcurrent relay coordination by adaptive protection scheme

open access: yes, 2016
Distributed Generation (DG) brought new challenges for protection engineers since standard relay settings of traditional system may no longer function correctly under the new conditions of DG.
Leonowicz, Zbigniew M.   +7 more
core   +1 more source

Recent advances in multifunctional soft robots: A materials–structures–systems co‐design perspective for synergistic integration

open access: yesFlexMat, EarlyView.
Abstract Soft robots, engineered from highly compliant materials, offer superior adaptability and safety in unstructured environments compared to their rigid counterparts. Recent advancements, fueled by bio‐inspiration and material programmability, have led to the rapid co‐evolution of their core modules: actuation, sensing, protection, energy, and ...
Qiulei Liu   +3 more
wiley   +1 more source

Bio‐inspired artificial retina with receptive fields for in‐sensor multiply‐and‐accumulate operations

open access: yesInfoMat, EarlyView.
We developed a bio‐inspired artificial retina in which curved artificial receptive fields composed of perovskite photoconductors perform multiply‐and‐accumulate operations through in‐sensor computing. This architecture simultaneously realized the structural efficiency of human eyes (compact single‐lens imaging system) and functional advantages of ...
Jisang Ha   +8 more
wiley   +1 more source

Quantifying temporal dynamics of greenhouse gas emissions in lake mesocosms: Deployment of a low‐cost measurement system

open access: yesLimnology and Oceanography: Methods, EarlyView.
Abstract Greenhouse gas (GHG) emissions from freshwater ecosystems contribute significantly to global carbon budgets, yet they remain poorly constrained due to limited high‐frequency measurements. We tested a low‐cost, high‐frequency GHG measurement system in a long‐term mesocosm experiment in Lemming, Denmark, over a 7‐month period, focusing on CO2 ...
Tuba Bucak   +6 more
wiley   +1 more source

Multifunctional Digital Protection Relay for Voltage and Current Disturbances in Power Networks

open access: yesEmitor: Jurnal Teknik Elektro
The protection system is an essential part of the electrical power system, designed to minimize disturbances quickly, accurately, and precisely. Excessive electricity use can lead to frequent voltage and current fluctuations, resulting in short circuits,
Andrian Riza   +3 more
doaj   +1 more source

Overcurrent Protection of Radial Distribution Network

open access: yesInternational Journal of Electrical Engineering and Applied Sciences, 2022
Overcurrent relay is the device that used in the protection of the power system network when there is any presence of fault. This paper represents the performance of  overcurrent protection of radial distribution network. The response of the current and
M. H. Hairi   +4 more
doaj  

Optical Skyrmions with Tunable or Reconfigurable Topology Using Spin‐Decoupled Metaoptics

open access: yesLaser &Photonics Reviews, EarlyView.
The work introduces advanced optical elements capable of generating and dynamically reconfiguring complex light patterns known as optical skyrmions. By precisely shaping light polarization at the nanoscale, a single engineered metasurface can generate and manipulate robust and tunable polarization textures in an efficient and scalable way.
Andrea Vogliardi   +5 more
wiley   +1 more source

Home - About - Disclaimer - Privacy