Results 41 to 50 of about 46,872 (257)

Frequency and Predictors of Renal Artery Stenosis in Patients Undergoing Simultaneous Coronary and Renal Catheterization [PDF]

open access: yesJournal of Tehran University Heart Center, 2012
Background: Atherosclerotic renal artery stenosis (ARAS) remains underdiagnosed due to its nonspecific demonstrations. We aimed to both estimate the frequency of ARAS in high-risk non-selected patients undergoing simultaneous coronary and renal ...
Navid Rokni   +4 more
doaj   +1 more source

Cross‐Scale Hierarchical Targeted Delivery System Based on Small‐Scale Magnetic Robots

open access: yesAdvanced Robotics Research, EarlyView.
This article reviews a cross‐scale hierarchical targeted delivery system that integrates magnetic continuum robots and magnetic microrobots. By combining rapid long‐range navigation with precise microscale targeting, the system overcomes key limitations of single‐scale approaches.
Junjian Zhou   +4 more
wiley   +1 more source

Intermittent claudication and severe renal artery stenosis are independently associated in hypertensive patients referred for renal arteriography

open access: yesClinics
OBJECTIVE: The purpose of this study was to evaluate the association between the presence of clinical symptoms of peripheral artery disease and severe renal artery stenosis in patients referred for renal angiography. METHOD: We included 82 patients with
Thiago Andrade Macedo   +6 more
doaj   +1 more source

Endovascular treatment of perigraft seroma in patient with prior hybrid thoracoabdominal repair using visceral bypass to relieve duodenal obstruction

open access: yesJournal of Vascular Surgery Cases and Innovative Techniques, 2022
Perigraft seroma (PS) is a postoperative complication occurring after prosthesis placement. A 48-year-old man who had previously undergone visceral debranching bypass surgery as a part of hybrid thoracoabdominal aortic repair was referred to our hospital
Tsutomu Doita, MD   +4 more
doaj   +1 more source

Magnetic Micro‐ and Nanorobots for Precision Thrombolysis: Design Strategies and Translational Challenges

open access: yesAdvanced Robotics Research, EarlyView.
Micro‐ and nanorobots for targeted thrombolysis. This perspective elaborates on the clinical indication of blood clot disorders and current limitations for treatment. As a novel, alternative solution, micro‐ and nanorobots can be used to treat and break down thrombi.
Joshua M. Mesfin   +3 more
wiley   +1 more source

Acute renal artery thrombosis after kidney transplantation

open access: yesJornal Vascular Brasileiro, 2014
Early kidney transplant loss as a result of acute thrombosis of the renal artery remains a constant and devastating complication, with an incidence of 0.2-7.5%.
Murat Özban   +5 more
doaj   +1 more source

The Development and Pilot Clinical Study of CD147 Targeted Antagonistic Peptide Probe for Tumor Imaging

open access: yesAdvanced Science, EarlyView.
This study establishes [68Ga]Ga‐DOTA‐AP9 as a first‐in‐human CD147‐targeted PET tracer with favorable safety and specific tumor uptake. Tracer accumulation correlates with CD147 expression in patients, enabling noninvasive quantification of CD147‐positive malignancies.
Xiaokun Ma   +10 more
wiley   +1 more source

Engineering Approaches to Modify Immunomodulatory Functions of Mesenchymal Stromal Cells (MSCs): Tissue Regeneration and Clinical Application

open access: yesAdvanced Science, EarlyView.
Mesenchymal stromal cells (MSCs) show promise for treating immune‐related disorders through immunomodulation and tissue regeneration. This review gives a brief overview of current clinical approval of MSC therapies. It also discussed how bioengineering, including genetic modification, biomaterial delivery, extracellular vesicles, and iPSC‐derived MSCs,
Sichen Yang   +6 more
wiley   +1 more source

Senescent Cell Derived Artificial Vesicle‐Based Senolytic Sonovaccine Platform with Augmented Lymph Node Delivery and Antigen Cross‐Presentation Efficacy

open access: yesAdvanced Science, EarlyView.
A senolytic sonovaccine platform (SenoVac) is developed, in which senescent cell‐derived vesicles serve as broad senescent cell antigen reservior. The “2‐step” click chemistry strategy for effective lymph node delivery, and ultrasound‐triggered endosomal escape to boost cross‐presentation, ensures efficient senescent cell clearance and disease ...
Liang Zhang   +10 more
wiley   +1 more source

Pathological Mechanism‐Inspired Biomimetic Nano‐Senotherapy for Reversing Experimental Atherosclerosis in ApoE−/− Mice

open access: yesAdvanced Science, EarlyView.
The biomimetic self‐assembly nanomedicine reversing atherosclerosis via senotherapy strategy. ABSTRACT The greatest challenge in atherosclerosis (AS) management lies in achieving lesion reversal, not merely slowing progression. Senescent cell accumulation—driven by continuous generation and apoptotic resistance—perpetuates plaque pathology and ...
Yuhan Tian   +9 more
wiley   +1 more source

Home - About - Disclaimer - Privacy