Results 21 to 30 of about 4,658,486 (302)
Reliability between repeated vertical oscillation measurements.
Reliability between repeated vertical oscillation measurements.
Dimitrios Pantazis (7209146) +5 more
core +1 more source
Application of Mixed Linear Models in the Analysis of Road Surface Features
The data were collected by researchers at the Road Research Institute, in a study investigating the impact of differentfactors on road surface strength.
Jurgita Židanavičiūtė +1 more
doaj +1 more source
Accuracy of velocities from repeated GPS measurements [PDF]
Today repeated GPS measurements are still in use, because we cannot always employ GPS permanent stations due to a variety of limitations. One area of study that uses velocities/deformation rates from repeated GPS measurements is the monitoring of crustal
V. Akarsu, D. U. Sanli, E. Arslan
doaj +1 more source
A Gaussian pseudolikelihood approach for quantile regression with repeated measurements [PDF]
To enhance the efficiency of regression parameter estimation by modeling the correlation structure of correlated binary error terms in quantile regression with repeated measurements, we propose a Gaussian pseudolikelihood approach for estimating ...
Zhu, Min, Wang, You-Gan, Fu, Liya
core +1 more source
Generalized Mixed Models - an application to longitudinal data of citrus canker
There are several techniques available for longitudinal data analysis. In the last decade, much emphasis has been placed on generalized mixed models. The present work is dedicated to give an overview of this technique, with emphasis on the formulation ...
João Pedro Serenini +3 more
doaj +1 more source
Empirical likelihood estimation in multivariate mixture models with repeated measurements
Multivariate mixtures are encountered in situations where the data are repeated or clustered measurements in the presence of heterogeneity among the observations with unknown proportions.
Yuejiao Fu +3 more
doaj +1 more source
Multiple Contrasts for Repeated Measures [PDF]
Abstract This article addresses the problem of multiple contrast tests for repeated measures. Three procedures are described and compared by simulations concerning the familywise error type I. The procedure based on sandwich estimators seems to be most robust, except for all-pair comparisons.
openaire +2 more sources
Effects of measurement intervals on the values of repeated auscultatory blood pressure measurements
Objective: For repeated measurements of blood pressure (BP) using the auscultatory method, current guidelines recommend intervals of 1–2 minutes; however, evidence to support this recommendation is insufficient.
Miki Imamura +5 more
doaj +1 more source
Background The association between soy isoflavones intake and cardiometabolic health remains inconclusive. We investigated the associations of urinary biomarkers of isoflavones including daidzein, glycitein, genistein, equol (a gut microbial metabolite ...
Shaoxian Liang +11 more
doaj +1 more source
Prognostic Value of Serial Galectin‐3 Measurements in Patients With Acute Heart Failure
BackgroundSeveral clinical studies have evaluated the association between galectin‐3 levels and outcome in patients with heart failure (HF). However, little is known about the predictive value of repeated galectin‐3 measurements. This study evaluates the
Laura C. van Vark +11 more
doaj +1 more source

