Results 171 to 180 of about 1,259,305 (207)
Some of the next articles are maybe not open access.

Magnetic Resonance Imaging of the Urolume Urethral Stent

The Journal of Urology, 1995
We discuss the use of magnetic resonance imaging of the pelvis in a patient with the UroLume urethral stent. This case demonstrates that magnetic resonance imaging is a safe and effective modality for imaging tissue surrounding the stent.
H P, Tay, S, Juma
openaire   +2 more sources

A thermosensitive material coated resonant stent for drug delivery on demand

Biomedical Microdevices, 2021
An electromagnetic energy source in the radio-frequency range delivers power to a stent circuit via resonant inductive coupling, allowing a thermally triggered release of gel via Joule heating. A gold-electroplated, medical-grade stainless steel stent, serving as the base of the prototype device, melts a coating made from an emulsion composed mainly of
Victor Bradley Bednar, Kenichi Takahata
openaire   +2 more sources

Evaluation of in‐stent stenosis by magnetic resonance phase‐velocity mapping in nickel‐titanium stents

Journal of Magnetic Resonance Imaging, 2005
AbstractPurposeTo evaluate different grades of in‐stent stenosis in a nickel‐titanium stent with MRI.Materials and MethodsMagnetic resonance phase velocity mapping (MR‐PVM) was used to measure flow velocity through a 9‐mm NiTi stent with three different degrees of stenosis in a phantom study.
Andrea D, Holton   +8 more
openaire   +3 more sources

Magnetic Resonance Angiography in the Evaluation of Carotid Stent Patency

Perspectives in Vascular Surgery and Endovascular Therapy, 2010
As more endovascular interventions are being used in the carotid circulation, including carotid angioplasty and stenting, a reliable imaging modality is needed to follow the results. Currently, duplex ultrasonography, magnetic resonance angiography (MRA), and angiography are the main modalities used.
Julie A, Rizzo   +3 more
openaire   +2 more sources

Experimental analysis on wireless heating of resonant stent for hyperthermia treatment of in-stent restenosis

Sensors and Actuators A: Physical, 2019
Abstract In-stent restenosis remains the most common problem with stent implantation. Hyperthermia therapy through moderate heating of implanted stent is expected to be an effective treatment for restenosis. Toward this goal, this work investigates a wirelessly powered resonant-heating stent device, with a focus on design improvement and experimental
Jiaxu Chen   +3 more
openaire   +1 more source

Simulations of the Stent Artifacts in Magnetic Resonance Imaging

IEEE Transactions on Magnetics, 2012
This paper presents an approach to simulate the stent artifacts in magnetic resonance imaging (MRI) based on electromagnetic (EM) analysis. The metallic stent disturbs the static magnetic field (B0) and the radiofrequency (RF) field during the MRI procedure, which consequently results in susceptibility artifacts and RF shielding artifacts in MR image ...
Yan Guo, Xiaohua Jiang
openaire   +1 more source

Magnetic resonance angiography of nonferromagnetic lliac artery stents and stent-grafts: A comparative study in sheep

CardioVascular and Interventional Radiology, 1999
To compare nonferromagnetic iliac artery prostheses in their suitability for patency monitoring with magnetic resonance angiography (MRA) using conventional angiography as a reference.In experiment 1, three Memotherm stents were inserted into the iliac arteries of each of six sheep: two "tandem" stents on one side and a single stent on the other side ...
K, Schürmann   +8 more
openaire   +2 more sources

[Magnetic resonance angiography of stents].

Journal de radiologie, 2000
To understand the behavior of stents during contrast-enhanced magnetic resonance angiography (MRA).Seven different types of stents are explored in vitro with spin echo (SE) T2 sequence and MRA sequences using classification of the intra-prothesis signal. Six patients with 11 different proximal stents are studied by Gadolinium enhanced MRA with the same
D, Drevet   +7 more
openaire   +1 more source

Dynamic Gadolinium DTPA-Enhanced Magnetic Resonance of Intravascular Stents

Investigative Radiology, 1998
Magnetic resonance contrast enhancement depends on the timing of image acquisition. Human trials have demonstrated efficacy of renal artery stents on salvage of renal function. This study assessed the ability of dynamic gadolinium (Gd)-DTPA administration to demonstrate renal and iliac artery stent patency compared to conventional angiography as the ...
R, Tello   +4 more
openaire   +2 more sources

Efficacy of Resonance® stent after failure of polymeric stent in the treatment of ureteral obstruction

The French Journal of Urology
Managing chronic ureteral obstruction is challenging. Compared with reinforced polymeric stents (RPS), Resonance JJ stents (RS) provide greater compression resistance and longer patency. This study aimed to assess the efficacy of RS versus RPS and to identify predictors of early change.A retrospective 14-year single-center study included patients who ...
Alexandre Baudry   +4 more
openaire   +2 more sources

Home - About - Disclaimer - Privacy