Results 81 to 90 of about 21,184 (136)
Some of the next articles are maybe not open access.

Protection systems against lightning-originated overvoltages in resonant grounded power distribution systems

2012 International Conference on Lightning Protection (ICLP), 2012
A joint research project between AES Sul, the Federal University of Itajuba and the University of Bologna aims at defining the required protections against lightning-originated overvoltages in a resonant grounded distribution system in order to achieve the adequate lightning performance level with minimum cost.
BORGHETTI, ALBERTO   +5 more
openaire   +1 more source

A Novel Measuring Method of Capacitance to Ground in Resonant Grounding System

2018 China International Conference on Electricity Distribution (CICED), 2018
In order to accurately and effectively realize the arc-suppression coil tuning, it is urgent to improve the measuring accuracy of the capacitance to ground in resonant grounding system. Because the existing measuring method does not consider the damping resistance which is connected in the grounding loop of arc-suppression coil, a novel measuring ...
Zhu Liang   +6 more
openaire   +1 more source

Grounding Failure Detection Based on Wavelets Method in Resonant Grounded Power Distribution System

2010 Second WRI Global Congress on Intelligent Systems, 2010
This paper analyses characteristics of single-phase ground fault and presents a fault line selecting method based on wavelet transform. Base on Sampling frequency, it selects the special frequency band, the singularity detection with wavelet is employed to obtain the polarities and magnitudes of the abrupt of current, and through comparing the ...
Yusheng Zhou   +4 more
openaire   +1 more source

First resonant neutral grounding implantation in Spanish distribution system

2001 IEEE Porto Power Tech Proceedings (Cat. No.01EX502), 2002
Changing the earthing system of medium voltage networks is a complex operation. It is necessary to take into account all the various technical aspects of the totality of the equipment involved in this process. Frequently, considerable additional economic investment is required as a result of this analysis of technical aspects.
A.J. Mazon   +5 more
openaire   +1 more source

Effects of grounding on distribution system harmonic resonance conditions

IEEE Transactions on Power Delivery, 1989
An analytic model is presented which predicts the impact of soil resistivity, grounding, and electric load on power system resonance characteristics. A parametric study is reported which illustrates the significance of these parameters and provides a quantitative evaluation of their effects.
A.P.S. Meliopoulos   +2 more
openaire   +1 more source

Multiband non-resonant antenna system with reduced ground clearance

2017 11th European Conference on Antennas and Propagation (EUCAP), 2017
Small and multiband antennas are crucial elements for wireless devices. On one hand, the space devoted to the antenna is small due to the presence of other electronic components in the device. On the other hand, the number of frequency bands with the inclusion of 4G is relevant.
Andujar, Aurora   +2 more
openaire   +1 more source

Systematic analysis of the harmonics in resonant grounding systems

2005 IEEE Russia Power Tech, 2005
This paper deals with the causes, propagation and resonance phenomena of harmonics in the zero sequence currents and line-to-earth voltages of medium voltage (MV) networks with grounding via Peterson coils. Of special interest is the relation of these harmonics between normal and earth fault operation of the network.
Peter Schegner   +2 more
openaire   +1 more source

Characteristic analysis of single-phase grounding fault in resonant grounded systems based-on HHT

2016 IEEE 11th Conference on Industrial Electronics and Applications (ICIEA), 2016
Transient analysis is carried out for the single-phase grounding fault in small current grounding system, the transient grounding current expression is derived, and the influence factors are analyzed. Introduces a method for non-stationary and non-linear signal analysis method-Hilbert Huang transform (HHT) to analyze the single phase grounding fault in
Yingwei Xiao   +3 more
openaire   +1 more source

A Ring Resonator System for Ground Subsurface Sensing

Subsurface Sensing Technologies and Applications, 2000
A circular ring placed parallel above the ground surface is analyzed. The analysis, based on transmission-line modeling, shows how the structure can be utilized for ground conductivity sensing purposes. It is shown that, once the operating frequency is tuned to a half wavelength resonance, the information on the amplitude ratio of two voltages (or two ...
openaire   +1 more source

Microwave resonance effects in paramagnetic singlet-ground-state systems

AIP Conference Proceedings, 1975
EPR in the excited Γ5(2) triplet state of Tm3+ in cubic TmP has been studied. From the temperature dependence of the g‐value, it was found that the fourth‐order term dominates in the crystal‐field, and the exchange interaction between Tm3+ ions is weakly antiferromagnetic.
K. Sugawara, C. Y. Huang, B. R. Copper
openaire   +1 more source

Home - About - Disclaimer - Privacy