Results 181 to 190 of about 3,991,609 (328)

Machine stability and dosimetry for ultra‐high dose rate FLASH radiotherapy human clinical protocol

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background The FLASH effect, induced by ultra‐high dose rate (UHDR) irradiations, offers the potential to spare normal tissue while effectively treating tumors. It is important to achieve precise and accurate dose delivery and to establish reliable detector systems, particularly for clinical trials needed to help the clinical transfer of FLASH‐
Patrik Gonçalves Jorge   +9 more
wiley   +1 more source

An investigation into the feasibility and efficacy of stereotactic radiosurgery for 1–3 cm single brain lesions on the ring‐mounted Halcyon LINAC

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose An evaluation of the accuracy, safety, and efficiency of the Halcyon ring delivery system (RDS) for stereotactic radiosurgery (SRS) treatment to relatively small (1–3 cm) brain lesions. Methods After completing the extensive in‐house quality assurance checks including Winston–Lutz test and independent dose verification via MD Anderson ...
Kate Hazelwood   +5 more
wiley   +1 more source

Flexural Behavior of Bidirectionally Graded Lattice

open access: yesAdvanced Engineering Materials, EarlyView., 2023
An experimental study of the bending behavior of bidirectional body‐centered cubic lattice beams is conducted in comparison to uniform and unidirectional counterparts of electron beam melted SS 316 L. Experimental results are used to develop and validate a finite element model which is subsequently used to conduct parametric studies to assess the ...
Chamini Rodrigo   +4 more
wiley   +1 more source

AAPM Task Group No. 249.B—Essentials and guidelines for clinical medical physics residency training program

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract The establishment of guidelines and curriculum standards for medical physics residency training is a critical component of setting expectations and competencies for the profession. Since the last publication of these standards, residency training has become integrated into the eligibility criteria for most medical physics certification bodies.
Jonathon A. Nye   +16 more
wiley   +1 more source

Investigation of the Uniformity of Gel Shrinkage by Imaging Tracer Particles Using X‐Ray Microtomography

open access: yesAdvanced Engineering Materials, EarlyView., 2023
A novel method for tracking structural changes in gels using widely accessible microcomputed tomography is presented and validated for various hydro‐, alco‐, and aerogels. The core idea of the method is to track positions of micrometer‐sized tracer particles entrapped in the gel and relate them to the density of the gel network.
Anja Hajnal   +3 more
wiley   +1 more source

Home - About - Disclaimer - Privacy