Results 11 to 20 of about 16,848 (165)
Characteristics of a new UT-type prefabricated joint for rectangular steel tubes under combined axial-moment loading. [PDF]
This study proposes a UT-type prefabricated joint incorporating adjustable sleeves (±5 mm tolerance) and an energy-dissipating segment to address the practical demands for construction tolerance management and plasticity assurance.
Menghan Sun, Luyao He, Zailin Yang
doaj +2 more sources
This paper proposes a new simplified restoring force characteristic model of the bending moment–rotation angle relationship for square concrete‐filled steel tube (CFT) beam‐columns to estimate the elastoplastic flexural‐shear behavior from short to ...
Toshiyuki Fukumoto, Koji Morita
doaj +3 more sources
Restoration of Joint Line Obliquity May Not Influence Lower Extremity Peak Frontal Plane Moments During Stair Negotiation [PDF]
Approximately 15% of total knee arthroplasty (TKA) patients remain dissatisfied after surgery, with joint line obliquity (JLO) potentially affecting patient outcomes.
Alexis K. Nelson-Tranum +5 more
doaj +2 more sources
Importation of band head spin for superdeformed bands in mass region A ∼ 60 - 90 using the variable moment of inertia model [PDF]
We are currently applying the variable moment of inertia model to nuclei in mass region A ∼ 60 - 90 in order to improve spectroscopic analysis of its rotational bands in the superdeformed region, which in turn is helpful in the band head spin prediction ...
K. A. Gado
doaj +1 more source
Static repair of multiple cracked beam using piezoelectric patches
This paper addresses the problem of repairing multiple cracked beams subjected to static load using piezoelectric patches. First, the problem is formulated and solved analytically for the case of two cracks that results in ratio of restoring moments ...
Tran Thanh Hai
doaj +1 more source
The hysteresis model of the friction pendulum bearing based on the moment balance theory
The hysteresis model of the friction pendulum bearing (FPB) is very important for predicting its seismic performance. The previous hysteresis model is based on the horizontal force balance theory and cannot analyze the moment required when the FPB ...
Tianbo Peng, Boyang Yan, Feng Li
doaj +1 more source
Restoring the Skew Quadrupole Moment in Tevatron Dipoles [PDF]
In early 2003 it was realized that mechanical changes in the Tevatron dipoles had led to a deterioration of the magnetic field quality that was hindering operation of the accelerator. After extensive study, a remediation program was started in late 2003 that will continue through 2005. The mechanical and magnetic effects are discussed. The readjustment
D.J. Harding +10 more
openaire +1 more source
Continuous Facial Motion Deblurring
We introduce a novel framework for continuous facial motion deblurring that restores the continuous sharp moment latent in a single motion-blurred face image via a moment control factor.
Tae Bok Lee, Sujy Han, Yong Seok Heo
doaj +1 more source
ObjectiveFemoral offset (FO) restoration is significantly correlated with functional recovery following total hip arthroplasty (THA). Accurately assessing the effects of FO changes on hip muscles following THA would help improve function and optimize ...
Xiangjun Hu +14 more
doaj +1 more source
In this study, a model test was carried out to evaluate the station-keeping performance of Korea Research Institute of the Ships and Ocean Engineering (KRISO) standard semi-submersible, K-Semi in the Deep Ocean Engineering Basin (DOEB).
Byeongwon Park +5 more
doaj +1 more source

