Results 201 to 210 of about 2,894,026 (347)
Calculation of nonlimit active earth pressure of retaining walls based on curved sliding surface. [PDF]
Gao G, Chen J, Qian B, Zhong W.
europepmc +1 more source
A methacrylamide β‐cyclodextrin‐based nanogel (MACD nGel) is developed to load the antimicrobial drug Metronidazole (MNZ) for topical delivery for the treatment of periodontitis. It is demonstrated that cyclodextrin nanogel (nGel) loaded with metronidazole provides an efficient drug delivery route but also has potential clinical applications and offers
Yanjing Ji +8 more
wiley +1 more source
Mechanical behavior of reservoir bank slope-pile-sheet structures under reservoir operation: Field monitoring and numerical simulation analysis. [PDF]
Cai Z +7 more
europepmc +1 more source
Computational Modeling Meets 3D Bioprinting: Emerging Synergies in Cardiovascular Disease Modeling
Emerging advances in three‐dimensional bioprinting and computational modeling are reshaping cardiovascular (CV) research by enabling more realistic, patient‐specific tissue platforms. This review surveys cutting‐edge approaches that merge biomimetic CV constructs with computational simulations to overcome the limitations of traditional models, improve ...
Tanmay Mukherjee +7 more
wiley +1 more source
Fragility analyses and strong ground motion response of mechanically stabilized earth retaining walls with plate anchors. [PDF]
Ansari Targhi M, Safi M, Noorzad A.
europepmc +1 more source
A vapor‐based porous coating applied within nitinol tubes demonstrated complete suppression of cellular and tissue ingrowth, overcoming a major limitation of implantable interstitial fluid collection devices. Molecular channeling and diffusion are analyzed with probe molecules, showing reliable transport in vitro and in vivo. The coating also achieved >
Yu‐Ming Chang +8 more
wiley +1 more source
Experimental dataset on the thermo-mechanical response of an energy piled wall section. [PDF]
Villegas L, Fuentes R, Narsilio GA.
europepmc +1 more source
This study presents a highly sensitive, oxidation‐resistant, biocompatible, and degradable Janus piezoresistive electronic skin for sustainable wearable electronics. The electronic skin exhibits sensitive and stable response across a broad pressure range, exceptional oxidation resistance, and Janus wettability.
Joon Kim +5 more
wiley +1 more source
Experimental study on the failure risk of existing metro station under unilateral large-scale excavation. [PDF]
Zhou F +6 more
europepmc +1 more source

