Results 81 to 90 of about 2,515,009 (257)
A chemically defined PEG‐based microgel platform enables scalable, reproducible production of three‐dimensional microgel‐iPSC constructs in multiple sizes. The system is compatible with high‐throughput automation and supports human iPSC expansion and differentiation within a single construct, including directed differentiation into cardiac organoids ...
Laura Klasen +8 more
wiley +1 more source
Active Targeting Across Scales in Medical Robotics
Medical robots can bridge the body's length scales by linking clinical access with controlled navigation and precise local action. This Review presents a cross‐scale access‐to‐action framework for active targeting and explains how anatomy, biological barriers, materials, actuation, and imaging shape application‐specific systems for diagnosis, therapy ...
Rujie Sun +11 more
wiley +1 more source
Wide Field Retinal Imaging –In Diagnosing of Retinal Pathologies
The peripheral retina is affected by many retinal pathologies. However, its documentation until recently was limited even with the montaging techniques available in the traditional fundus cameras.
Richa Ranjan, Neha Bharti, Bhupesh Singh
doaj +1 more source
Background Retinoschisis and retinal detachment are distinguished based on features in clinical examination. Even to skilled examiners, some cases may be diagnostic challenges.
Himanshu K. Banda +2 more
doaj +1 more source
Live imaging has become the favorite method in recent years to study the protein transport, localization and dynamics in live cells. Protein transport is extremely essential for proper function of photoreceptors.
Mohammad Haeri +3 more
doaj +1 more source
The physics, instruments and modalities of retinal imaging
Computer analysis of retinal images is of increasing importance in healthcare. The characteristics of retinal images are determined by the physics and principles of the retinal imaging process and hence the appearance of images varies in both profound
Andrew R. Harvey +8 more
core +1 more source
In this study, we show that retinal matrix stiffness is increased in diabetic mice. Using engineered human vascular models with controlled matrix stiffness, we demonstrate that stiffening activates focal adhesion kinase (FAK) signaling in pericytes, suppresses Notch signaling, and disrupts vascular morphology.
Emily Warren +6 more
wiley +1 more source
High resolution retinal imaging to evaluate laser and light safety in the retina for near and long term health effects [PDF]
textThe purpose of this research was to investigate detect and monitor laser-tissue interactions at threshold and potentially sub-threshold levels of injury.
Pocock, Ginger Madeleine
core
Transparent microelectrode arrays enable simultaneous optical and electrical electrophysiology with high spatiotemporal resolution, allowing multimodal observations of dynamic biological systems. Advances in materials and device architectures improve device performance by addressing key trade‐offs between optical transparency, impedance, and ...
Michael Abraham Listyawan +6 more
wiley +1 more source
Self‐Sealing Microneedles Improve Precision and Reduce Reflux in Subretinal Cell Transplantation
Ultrafine 49G microneedles enable subretinal delivery of induced pluripotent stem cell‐derived retinal pigment epithelial cells through a 50 µm outer diameter tip. Compared with conventional 38G microcannulas, these microneedles reduce cell suspension reflux in a rabbit model, highlighting the potential of microinvasive delivery instruments to improve ...
Jared Ching +9 more
wiley +1 more source

