Results 11 to 20 of about 97,342 (313)

Experimental Research on Damping Effect of Double-Layer Tuned Mass Damper for High-Rise Structure

open access: yesShock and Vibration, 2021
A double-layer tuned mass damper (DTMD) has advantages of wide damping frequency band and strong robustness. At present, there is a lack of seismic design methods for high-rise structures based on DTMDs.
Botan Shen   +6 more
doaj   +1 more source

Developing and Applying a Double Triangular Damping Device with Equivalent Negative Stiffness for Base-Isolated Buildings

open access: yesBuildings, 2023
A passive double triangular damping (DTD) device with equivalent negative stiffness is proposed in this study. The DTD device consists of transmission systems and triangular damping systems.
Tianwei Sun   +3 more
doaj   +1 more source

Compression performance analysis of multi-scale modified concrete based on response surface method

open access: yesCase Studies in Construction Materials, 2022
The natural multi-scale defects in concrete are important factors affecting the performance. To comprehensively improve the performance of concrete, a method of adding variety materials into concrete to improve the defects from nano-micron-millimeter ...
Haoxiang He   +3 more
doaj   +1 more source

Retrofitting parallelism onto OCaml [PDF]

open access: yesProceedings of the ACM on Programming Languages, 2020
OCaml is an industrial-strength, multi-paradigm programming language, widely used in industry and academia. OCaml is also one of the few modern managed system programming languages to lack support for shared memory parallel programming. This paper describes the design, a full-fledged implementation and evaluation of a mostly-concurrent garbage ...
Sivaramakrishnan, KC   +8 more
openaire   +3 more sources

Europe’s constitutional retrofit [PDF]

open access: yesGlobal Constitutionalism, 2023
AbstractThe various and diverse academic responses to the Conference on the Future of Europe’s efforts at democratic renewal, including those by Ben Crum, Markus Patberg and Sandra Seubert, speak not only to the lack of a clear institutional locus or pathway associated with the Conference, but also to differing understandings of the basic conditions of
openaire   +1 more source

Retrofitting Fat Metabolism [PDF]

open access: yesCell Metabolism, 2009
In this issue of Cell Metabolism, Liao and colleagues have applied a novel synthetic approach to fight obesity in animals by engineering the plant glyoxylate shunt in vivo (Dean et al., 2009). The idea of introducing an entirely foreign metabolic pathway opens up opportunities for understanding metabolism and creating novel potential therapeutic ...
Pei, Liming, Evans, Ronald M.
openaire   +2 more sources

Gravity mediation retrofitted [PDF]

open access: yesJournal of High Energy Physics, 2013
Most discussion of metastable dynamical supersymmetry breaking (MDSB) has focussed on low energy breaking, as in gauge mediation. It is of interest to consider possible implications for intermediate scale breaking ("gravity mediation"), especially as the early LHC results suggest the possibility that supersymmetry, if broken at relatively low energies,
Bose, Milton, Dine, Michael
openaire   +2 more sources

Seismic fragility analysis of the transfer and purging chamber in a nuclear power plant based on incremental dynamic analysis

open access: yesJournal of Radiation Research and Applied Sciences, 2022
The seismic fragility of the transfer and purging chamber in a nuclear power plant is assessed in this paper based on the incremental dynamic analysis method.
Xuchen Liu   +4 more
doaj   +1 more source

Effect assessment for the interaction between shaking table and eccentric load

open access: yesScientific Reports, 2022
Electro-hydraulic shaking table is an essential experimental apparatus to evaluate structural performance under actual vibration condition. The control-structure interaction (CSI) between shaking table and eccentric load has lately received considerable ...
Juke Wang   +5 more
doaj   +1 more source

Time-averaged single sided ventilation rates and thermal environment in cooling mode for a low energy retrofit envelope [PDF]

open access: yes, 2014
Non-invasive, scalable, building retrofit solutions are very attractive deep renovation techniques to improve energy efficiency in existing buildings; this includes natural ventilation for cooling due to the low impact nature of the installation. However,
Kolokotroni, M, O'Sullivan, PD
core   +1 more source

Home - About - Disclaimer - Privacy