Blade shapes (leading‐edge geometry and thickness) in rotodynamic blood pumps were systematically evaluated. Thinner blades improve pump efficiency by reducing blockage effects, while neither blade thickness nor leading‐edge geometry shows clear hemocompatibility benefits. Overall, blade shape has a limited impact on hemocompatibility, indicating it is
Benjamin Torner +7 more
wiley +1 more source
Development of Implantable Right Ventricular Assist Device
論文(Article)
openaire +1 more source
Consensus surrounding the management of VA ECMO and left ventricular mechanical unloading for cardiogenic shock (CS) is limited. We thus conducted a national survey of practice patterns in the treatment of CS to characterize such variability, finding large heterogeneity in CS diagnosis, VA ECMO initiation, and LVMU strategies.
Dustin M. Anderson‐Bell +16 more
wiley +1 more source
Preventable geometric failure modes, such as outflow graft kinking and inflow malposition, frequently cause HeartMate 3 dysfunction. This study identifies these complications as key drivers of device‐related morbidity, highlighting the importance of optimized surgical positioning to ensure long‐term device performance and improved clinical outcomes ...
Ali Saad Merzah +17 more
wiley +1 more source
Monitoring Mitochondrial Function With High‐Resolution Respirometry During Ex‐Situ Heart Perfusion
Normothermic ESHP preserves mitochondrial respiratory function over 6 h in a porcine model (n = 6): OXPHOS capacities across NADH‐, fatty‐acid‐, and succinate‐linked pathways remain stable, with reduced cytochrome‐c control efficiency indicating improved outer‐membrane integrity. HRR provides a rapid, actionable readout for organ assessment.
Lukas Stastny +12 more
wiley +1 more source
Integrating silver‐plated wound dressings into DLES care presents a safe and effective strategy for DLI prevention. Key findings include a 100% infection‐free rate in the Silverlon group, no NPWT and hospital readmission in the Silverlon group, and no severe DESTINE stages (3, 4) in the Silverlon group.
Barbara Veiter +9 more
wiley +1 more source
Experimental Extracorporeal Circulation System: A Pilot Study in Rats
A miniature extracorporeal circulation (ECC) system was developed for reproducible rodent studies. This system incorporates an integrated heat exchanger and a silicone membrane oxygenator within a double‐lumen circuit, resulting in an ultralow priming volume of < 1.5 mL.
Akira T. Kawaguchi +7 more
wiley +1 more source
LVAD‐associated aortic regurgitation impairs circulatory support, with limited surgical and off‐label options. In a multicenter registry (n = 30), the AR‐dedicated JenaValve Trilogy TAVR eliminated AR, achieving 96.7% (29/30) technical success and 93.3% (28/30) device success (VARC‐3), with 3.3% (1/30) 30‐day mortality.
Hristian Hinkov +13 more
wiley +1 more source