Results 41 to 50 of about 13,107,152 (246)

Hierarchical transformation-guided image registration for two-dimensional gel electrophoresis image

open access: yesJournal of Algorithms & Computational Technology, 2020
Many proteomics studies have been devoted to investigate the gel-based methods for separation and fractionation of complex protein mixture extracted from tissues, cells, and other biological specimens.
Lifang Wei   +5 more
doaj   +1 more source

Optimization Techniques for Semi-Automated 3D Rigid Registration in Multimodal Image-Guided Deep Brain Stimulation

open access: yesCurrent Directions in Biomedical Engineering, 2023
Multimodal image registration is vital in Deep Brain Stimulation (DBS) surgery. DBS treats movement disorders by implanting a neurostimulator device in the brain to deliver electrical impulses. Image registration between computed tomography (CT) and cone
Al-Jaberi Fadil   +4 more
doaj   +1 more source

Analysis of ICP variants for the registration of partially overlapping time-of-flight range images [PDF]

open access: yes, 2010
The iterative closest point (ICP) algorithm is one of the most commonly used methods for registering partially overlapping range images. Nevertheless, this algorithm was not originally designed for this task, and many variants have been proposed in an ...
Michael J. Cree   +5 more
core   +2 more sources

Non-rigid image registration of 4D-MRI data for improved delineation of moving tumors

open access: yesBMC Medical Imaging, 2020
Background To increase the image quality of end-expiratory and end-inspiratory phases of retrospective respiratory self-gated 4D MRI data sets using non-rigid image registration for improved target delineation of moving tumors. Methods End-expiratory and
Stefan Weick   +9 more
doaj   +1 more source

A Rigid Image Registration by Combined Local Features and Genetic Algorithms

open access: yesApplied Computer Systems, 2023
Image registration is an essential pre-processing step required for many image processing applications such as medical imaging and computer vision. The aim is to geometrically align two or more images of the same scene by establishing a mapping that ...
Meskine Fatiha, Mezouar Oussama
doaj   +1 more source

Landmark-guided deformable image registration for accurate cumulative dose evaluation in lung reirradiation

open access: yesPhysics and Imaging in Radiation Oncology
Background and purpose: Dose summation in thoracic reirradiation is challenging due to anatomical changes and limitations of rigid image registration. Deformable image registration offers improved accuracy but requires careful evaluation before clinical ...
Marija Popovic   +4 more
doaj   +1 more source

Image Similarity Metrics in Image Registration [PDF]

open access: yes, 2010
Measures of image similarity that inspect the intensity probability distribution of the images have proved extremely popular in image registration applications. The joint entropy of the intensity distributions and the marginal entropies of the individual
Melbourne, A, Ridgway, G, Hawkes, DJ
core  

Early Clinical, Imaging, and Pathological Characteristics of SRPK3/TTN‐Digenic Myopathy

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Objective SRPK3/TTN‐digenic myopathy was recently established as a skeletal muscle myopathy caused by digenic inheritance. This study characterizes the early clinical presentation of SRPK3/TTN‐digenic myopathy in one previously reported and seven newly identified pediatric patients.
Rotem Orbach   +23 more
wiley   +1 more source

Association Between Motor Pathway Damage and Motor Deficit in Upper and Lower Limb in People With MS

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Objective Corticospinal tract damage is common in people with MS, but the degree of clinical symptoms varies. We hypothesize that corticospinal tract lesions are more extensive and severe in people with MS with motor impairments in both upper and lower limbs.
Mathilde Liffran   +13 more
wiley   +1 more source

Registration error of the liver CT using deformable image registration of MIM Maestro and Velocity AI

open access: yesBMC Medical Imaging, 2017
Background Understanding the irradiated area and dose correctly is important for the reirradiation of organs that deform after irradiation, such as the liver.
Nobuyoshi Fukumitsu   +11 more
doaj   +1 more source

Home - About - Disclaimer - Privacy