Results 121 to 130 of about 2,185,218 (244)

Percutaneous Trans-septal Mitral Valve-in-Ring Implantation Using a Transcatheter Balloon-Expandable Transcatheter Heart Valve With Elective Intra-Procedural Artero-Venous ECMO in a Patient With Severely Reduced Left Ventricular Ejection Fraction

open access: yesFrontiers in Cardiovascular Medicine, 2019
Percutaneous mitral valve-in-valve implantation is an emerging option in patients with surgical bioprosthesis failure or failing mitral annuloplasty and increased surgical risk.
Francesca Ristalli   +6 more
doaj   +1 more source

Mycobacterium goodii endocarditis following mitral valve ring annuloplasty

open access: yesAnnals of Clinical Microbiology and Antimicrobials, 2017
BackgroundMycobacterium goodii is an infrequent human pathogen which has been implicated in prosthesis related infections and penetrating injuries. It is often initially misidentified as a gram-positive rod by clinical microbiologic laboratories and ...
Rohan B. Parikh, M. Grant
semanticscholar   +1 more source

Personalized computational modeling protocol for virtual MV repair to perform leaflet resection and annuloplasty ring implantation followed by dynamic simulation of MV function.

open access: yes, 2015
Personalized computational modeling protocol for virtual MV repair to perform leaflet resection and annuloplasty ring implantation followed by dynamic simulation of MV function.
Hyunggun Kim (759176)   +3 more
core   +1 more source

Three-dimensional computed tomography analysis of the mitral annulus for mitral annuloplasty in 100 cases of robotic mitral valve repair

open access: yesFrontiers in Cardiovascular Medicine
ObjectivesThis study aimed to evaluate the efficacy of preoperative computed tomography in assessing mitral annulus anatomy and the posterior annular plication rate in mitral valve repair with annuloplasty.MethodsFrom July 2018 to August 2023, we ...
Yosuke Takahashi   +10 more
doaj   +1 more source

Annuloplasty for valve repair with a new biodegradable ring: an experimental study

open access: yes, 2006
The biodegradable ring was recently developed for mitral and tricuspid annuloplasty. The study aim was to assess the histological biocompatibility of the biodegradable ring and orifice area growth in a porcine ...
Orrit, Xavier   +9 more
core  

Bicuspid Ring Annuloplasty and Leaflet Reconstruction After Failed Bicuspid Valve Repair and Aortic Root Remodeling

open access: yes, 2018
ObjectivesAfter bicuspid aortic valve (BAV) repair, annular dilatation can cause recurrent valve dysfunction. This video illustrates a patient undergoing BAV re-repair using ring annuloplasty for progressive annular dilatation and recurrent aortic ...
Rankin, J. Scott (5340587)   +2 more
core   +1 more source

Four-year outcome of the tricuspid valve leaflet augmentation and ring annuloplasty in dextrocardia. [PDF]

open access: yesIndian J Thorac Cardiovasc Surg, 2023
Honda K   +3 more
europepmc   +1 more source

Median maximum principal stress and median maximum principal strain of AML and PML for deformed FE models after Classic ring (left panel) and GeoForm ring (right panel) annuloplasty and PMR.

open access: yes, 2018
Median maximum principal stress and median maximum principal strain of AML and PML for deformed FE models after Classic ring (left panel) and GeoForm ring (right panel) annuloplasty and PMR.
Charles Primiano (4424299)   +6 more
core   +1 more source

Post-repair Doppler ultrasound data following the actual surgical repair (quadrangular resection and ring annuloplasty) to treat the posterior MV prolapse.

open access: yes, 2015
Post-repair Doppler ultrasound data following the actual surgical repair (quadrangular resection and ring annuloplasty) to treat the posterior MV prolapse.
Hyunggun Kim (759176)   +3 more
core   +1 more source

Home - About - Disclaimer - Privacy