Results 171 to 180 of about 1,100 (215)
Some of the next articles are maybe not open access.
Settings of ROCOF relays for islanding detection of wind turbine
2011 International Conference on Advanced Power System Automation and Protection, 2011One of the most important methods in the field of anti islanding protection of wind turbine is rate of change of frequency (ROCOF). When a self-excitation induction generator is islanded, voltage and frequency will vary and in most cases, exceed from legal range that can be detected by voltage relays, frequency relays and ROCOF relays.
Hossein Kazemi Karegar
exaly +2 more sources
Loss-of-Mains Detection by Internet Based Rocof
This paper considers the enhancement of loss-of-mains detection by use of a differential rate-of-change-of-frequency relay to reduce nuisance tripping and improve sensitivity to small excursions in frequency. The telecommunications media which might carry the differential ROCOF signal are reviewed with a focus on channel latency, bandwidth and security.
Laverty, D.M. +3 more
openaire +5 more sources
ROCOF of higher order for semi-Markov processes
Applied Mathematics and Computation, 2023zbMATH Open Web Interface contents unavailable due to conflicting licenses.
Guglielmo D'Amico, Filippo Petroni
openaire +3 more sources
This research proposes a new perspective for identification of wideband stability in virtual synchronous generator (VSG) with virtual impedance control strategy.
Chang Li, Yijia Cao, Yaqian Yang
exaly +2 more sources
Adaptive Frequency Estimation Method for ROCOF Islanding Detection Relay
Rate-of-change-of-frequency (ROCOF) is one of the most popular local islanding detection methods due to its simplicity and low cost. However, the method suffers from significant non-detection zone (NDZ) and experiences security issues due to non ...
Maciej Grebla +2 more
exaly +2 more sources
Hybrid ROCOF Relay for Islanding Detection
Journal of Electrical Engineering & Technology, 2021Distributed generation (DG) is increasing in day to day life to meet the global energy consumption demand. One of the major problems with such DG is islanding. The islanding is caused in the grid connected system when a part of DG is disconnected from the main grid and continues to feed the load connected.
Ch. Rami Reddy +6 more
openaire +1 more source
2018 IEEE Power & Energy Society Innovative Smart Grid Technologies Conference (ISGT), 2018
Rate of change of frequency is one of the parameters that a phasor measurement unit is expected to measure. Difficulty has been reported with the measurement, and whether or not it can even be measured in the real world has been questioned. Using a fitting algorithm, we show that with what seem like reasonable levels of harmonic distortion and noise on
Harold Kirkham, Shikhar Pandey
openaire +1 more source
Rate of change of frequency is one of the parameters that a phasor measurement unit is expected to measure. Difficulty has been reported with the measurement, and whether or not it can even be measured in the real world has been questioned. Using a fitting algorithm, we show that with what seem like reasonable levels of harmonic distortion and noise on
Harold Kirkham, Shikhar Pandey
openaire +1 more source
Performance of ROCOF protection in microgrid
2015 5th International Conference on Electric Utility Deregulation and Restructuring and Power Technologies (DRPT), 2015Accompanying the fast development of DG system and more DGs connecting to the distribution system, some new problems appear in protection technique area about grid-connected DG system, among which islanding is a typical and major one. Unplanned islanding will bring many problems to the grid: It threatens the life safety of power line maintaining staff ...
Bohan Liu +3 more
openaire +1 more source
Marginal improvement of AUFLS using ROCOF
2015 Australasian Universities Power Engineering Conference (AUPEC), 2015This paper proposes a scheme that integrates rate of change of frequency (ROCOF) and under frequency (UF) elements to design more effective load shedding response. A new load block activation algorithm is also introduced that improves the overall load shedding (LS) performance.
Kaium Uz Zaman Mollah +1 more
openaire +1 more source
Advanced ROCOF protection Of synchronous generator
ISGT 2011, 2011The penetration of distributed generation (DG) in electrical power systems is rapidly increasing these days and more attention is drawn to maintaining a healthy distribution system. Islanding operation of DG is one of the biggest challenges. When Islanding occurs, the power supply from the main grid is interrupted which causes a problem when ...
null Bohan Liu +3 more
openaire +1 more source

